Wachendorff DA9602 Скачать руководство пользователя страница 3

 Operating manual 

 

 

 

- 3 - 

1. Introduction 

Dear valued Customer! 

Thank you for purchasing and using a product from our company. The universal digital panel meter 
DA9602 from Wachendorff Prozesstechnik GmbH & Co. KG can be used for a number of 
applications. 
For getting the highest effort out of this unit, we kindly ask you to follow the mentioned instructions 
below: 
 

Every person who is involved with the installation or usage of this unit, must read carefully 
and understand the installation manual and safety instructions! 

2. Safety 

instructions 

2.1 General 

information 

To ensure the safe operation of this unit the instructions that appear in this manual must be strictly 
observed. In addition, when used all applicable legal and safety regulations for the respective 
application must be observed. The same applies correspondingly to the use of accessories. 

 

2.2  

Intended usage 

Units from the DA9602R are used for collecting and displaying a variety of analogue sensor 
signals. Any other use is regarded not in accordance with the intended usage. 
 

The Wachendorff universal panel meters DA9602 are not meant to be used as sole safety 
means to prevent dangerous situations on machinery and installations. Machinery and 

intallations must be designed that fault conditions can not lead to harmful situations to operating 
personnel (e.g. by independent limit value switches, mechanical locking etc.). 

2.3  

Qualified personnel 

Units from the Wachendorff universal panel meter DA9602R must only be operated in accordance 
with the technical specifications by qualified personnel. Personnel regarded qualified is familiar with 
the installation, assembly, putting into operation and operation of the units and possesses adequate 
professional qualification for the task. 

2.4  

Remaining hazards 

Units from the Wachendorff universal panel meter DA9602R are state of the art and safe to 
operate. A risk of danger can occur when deployed and operated improperly by untrained 
personnel.  
 
In this manual remaining hazards are marked by the following warning symbol: 
 

 
 
 
 

2.5 Legal 

responsibility 

Liability for material defects and defects of this documentation, particularly for the accuracy, 
correctness, freedom of protection or third party rights, completeness and/or usability - except for 
willful misconduct or gross negligence - is excluded. 

This symbol indicates that non-observance of the safety guidelines may 
cause hazards to persons even serious injury or death and/or the 
possibility of property damage. 

Содержание DA9602

Страница 1: ...ndorff Prozesstechnik GmbH Co KG Industriestra e 7 D 65366 Geisenheim Tel 49 6722 9965 20 Fax 78 All Information without warranty errors and changes reserved Universal display DA9602 Operating manual...

Страница 2: ...on 6 4 10 F1 and F2 function keys 6 4 11 Overflow alarm 7 4 12 Minimum and maximum 7 4 13 24 VDC auxiliary voltage source 7 4 14 Interface 7 5 Installation 7 5 1 Mechanically installation 7 5 2 Electr...

Страница 3: ...vent dangerous situations on machinery and installations Machinery and intallations must be designed that fault conditions can not lead to harmful situations to operating personnel e g by independent...

Страница 4: ...mocouple K Range 150 C to 1370 C 238 F to 2498 F Thermocouple T Range 160 C to 400 C 256 F to 752 F Thermocouple N Range 270 C to 1300 C 454 F to 2372 F Thermocouple R Range 50 C to 1760 C 58 F to 320...

Страница 5: ...oint defined by ALrF SPA1 using alarm 1 as an example ALrF PV ALrF SPA1 ALrF PV ALrF SPA1 SPA1 positive SPA1 negative Alarm of the Maximum Differential Value It triggers when the value of the PV is ab...

Страница 6: ...ory and can also be presented at the indicator display by choosing TOTAL screen which is identified by the symbol TOT This symbol is always presented when the TOTAL is being presented The TOTAL value...

Страница 7: ...W identify if the part being displayed is the SP most significant part HIGH or the least significant part LOW The totalization alarm SP is defined through the values SPA1 and SPA2 This two parameters...

Страница 8: ...e 5 3 Recommendations for the installation To minimize the pick up of electrical noise the low voltage DC connections and the sensor input wiring should be routed away from high current power conducto...

Страница 9: ...cording to the desired behavior The user shall understand the importance of each parameter and determine a valid condition or a valid value for each one of them The configuration parameters are groupe...

Страница 10: ...SP decimal point SetPoint Alarm Alarm SP Value that defines the point of activation of the alarm outputs For the alarms programmed with the functions of the type Band and Differential these parameter...

Страница 11: ...indication range when the input types of 0 20 mA 4 20 mA 0 50 mV 0 5 V and 0 10 V are used Defines the function to be executed by F1 and F2 keys No associated function Executes Batch Function Addition...

Страница 12: ...p the Level of Protection See Table 03 Frequency Frequency of the local electrical network Serial number 4 most significant digits Serial number 4 least significant digits 8 6 Password protection The...

Страница 13: ...in the event of it being forgotten The Master Password doesn t grant access to all parameters only to the Password Change parameter After defining the new password the protected parameters may be acce...

Страница 14: ...0 mV 10 M 0 to 5 V 0 to10 V 500 k 4 to 20 mA 100 Measuring of the Pt100 3 wire type 0 00385 with compensation of the cable length max 50 meters excitation current of 0 170 mA OUTPUT Output ALARM1 Rela...

Страница 15: ...nical content within this document can be modified without notice The content of this document is content of a recurring audit In losses due to fire earthquake interventions by third or other accident...

Отзывы: