7.1.14 Remove  and  SCRAP the  diaphragm (15)  from  the 
piston (13). 

 

7.1.15 Remove the diaphragm follower (16) from the piston 
stem (17). 

 

7.1.16 Remove and SCRAP the vent protector seal (27) from 
the washer (26) in the bottom of the housing (19).  The seal 
has an interference fit with the washer and can be pulled out. 

 

7.1.17 

 

WARNING:  During the following procedure, 

the  spring (24)  will  be  compressed.  Exercise care so 
that  no  parts  are  inadvertently  expelled  from  the 
assembly.   Inadvertently  expelled  parts  may  cause 
bodily injury and/or damage to property.

 

 

Carefully depress the washer (25) and spring (24) into the 
housing  (19),  then,  while holding these  parts  depressed, 
remove the retaining ring (26) from its groove in the housing 
(19).  Slowly release the hold on the washer (25) and spring 
(24) permitting the spring (24) to extend its full travel. 

 

7.1.18 Remove the washer (25), spring (24) and exhaust valve 
with seal (21) from the housing (19). 

 

7.1.19 Remove and SCRAP the exhaust valve seal (22) from 
the exhaust valve (23). 

 

7.2  Cleaning and Inspecting

 

 

7.2.1   NON-REUSABLE PARTS

 

 

7.2.1.1 

ALL 

gaskets, o-rings, seals, the wire mesh strainer 

and diaphragms 

ARE TO BE SCRAPPED 

and replaced with 

NEW 

Wabtec Corporation parts. 

 

NOTE: 

A Kit of Rubber Parts for the VX Vent Valve Portion is 

available and  may be  obtained by ordering Part Number 
654716.  See Parts Catalog 3211-7, S.7 for parts included in 
this  Kit. 

 

7.2.2   BODY AND HOUSING

 

 

IMPORTANT:    

Cleaning solvents are to be used in a well 

ventilated area. 

 

7.2.2.1    Using a clean, lint-free rag that has been saturated 
with the cleaning solvent, as described in Section 6.1.1, clean 
the interior and exterior surfaces of the body (2) and housing 
(19). 

7.2.2.2   After  these  parts  are  cleaned,  they 

MUST  BE 

completely dried.  Use a low pressure jet of clean, dry air to 
blow the parts dry. 

 

7.2.2.3    Inspect the body (2) and housing (19) for damage. 
Pay particular attention to the bushings within the housing. 
The  bushings should be free  of  nicks, scratches and pits. 
Replace the body and/or housing if found to be damaged, or 
if they show signs of excessive wear, or if they are in such a 
condition that may result in the unsatisfactory operation of 
the VX Vent Valve Portion. 

 

7.2.3   EXHAUST VALVE

 

 

7.2.3.1   Dip the exhaust valve (23) in a bath of the prescribed 
cleaning solvent, Section 6.1.1 and promptly wipe it  clean 
with a clean, lint-free cloth. 

 

7.2.3.2    Blow the exhaust valve (23) completely dry, using a 
low pressure jet of clean, dry air. 

 

7.2.3.3   Inspect the exhaust valve (23).  It is to be replaced 
if it is found to be nicked, cut, cracked, broken, or damaged 
in any way, or if it is in such a condition that may result in the 
unsatisfactory operation of the VX Vent Valve Portion. 

 

7.2.4   REMAINING REUSABLE PARTS

 

 

7.2.4.1      Wash all remaining reusable parts using the cleaning 
solvent as described in Section 6.1.1. 

 

7.2.4.2   The springs (8, 24) may be wire brushed to assist 
in the removal of any dirt, rust or scale. 

 

7.2.4.3    After the parts have been cleaned, they 

MUST BE 

completely dried.   Use a  low pressure jet  of  clean, dry air 
blow to the parts dry. 

 

7.2.4.4   Inspect the piston (13).  Replace the piston if it is 
bent, broken, damaged, excessively worn, or if it is in such a 
condition that may result in the unsatisfactory operation of 
the VX Vent Valve Portion. 

 

7.2.4.4.1  Remove the 

1

/

8

" choke plug (14) from the piston 

(13) and place it in a bath of the cleaning solvent to soak. 

 

7.2.4.4.2  While  the  choke  plug  is  soaking,  inspect  the 
opening in  the piston (13) from which the choke plug (14) 
was removed to be sure that it is clean and free of dirt.   If 
necessary, blow the opening clean with a low pressure jet of 
clean, dry air. 

Содержание VX

Страница 1: ...pecification At the time this device is applied to the brake equipment arrangement a stationary vehicle test must be made to insure thatthis device functions properly in the total brake equipment arra...

Страница 2: ...valve diaphragm assembly Brake pipe air flow continues through the passage in the seated piston where it is blocked by the exhaust valve Brake pipe air under pressure in cavity b1 flows through the c...

Страница 3: ...unseated piston stem at the exhaust valve Cavity b2 is exhausted quickly due to its small volume 2 3 EMERGENCY SECOND STAGE The rapid exhaust of air pressure from cavity b2 creates a differential on t...

Страница 4: ...hich must be less than 30 p s i g to blow parts clean or to blow them dry after being cleaned with a solvent will cause particles of dirt and or droplets of the cleaning solvent to be airborne Wire br...

Страница 5: ...to the installation of this choke plug in the piston 6 3 1 Locking Sealant Wabtec Corporation Specification M 7499 05 such as Loctite Corporation TL 242 is required for application to the threads of...

Страница 6: ...4211 7 S 7 Operation Maintenance Instruction September 2017 Page 6 of 10 Figure 4 VX Vent Valve Portion...

Страница 7: ...r these parts are cleaned they MUST BE completely dried Use a low pressure jet of clean dry air to blow the parts dry 7 2 2 3 Inspect the body 2 and housing 19 for damage Pay particular attention to t...

Страница 8: ...t is in such a condition that may result in the unsatisfactory operation of the VX Vent Valve Portion 7 3 ASSEMBLY 7 3 1 Apply Number 2 Silicon Grease Wabtec Corporation Specification M 7680 2 to a NE...

Страница 9: ...he filling piece 9 7 3 17Install three 8 x 1 2 button head screws 5 through the aligned holes of the diaphragm clamping ring 6 and the filling piece 9 Equally tighten the screws to maintain alignment...

Страница 10: ...4211 7 S 7 Operation Maintenance Instruction September 2017 Page 10 of 10 Wabtec Corporation 1001 Air Brake Avenue Wilmerding PA 15148 412 825 1000 Fax 412 825 1019 www wabtec com...

Отзывы: