27
Appendix II
Fig. 20
R
≥
10 x D
FASTENER
ZIP TIE
ZIP TIE
Bend radius (R) equal to
or greater than 10 times
cable diameter (D).
R
≥
10 x D
First fastener must be
a minimum 6 inches (152 mm)
and a maximum of 12-inches
(305 mm) from connector.
TANK MOUNTING - ECU FRONT VIEW
FASTENER
4014396a
4"
Max.
12"
R
4"
R
Max.
12"
CORRECT POWER AND GIO/MODULATOR CABLE STRAIN RELIEF FOR ABS 2S/2M-4S/3M
6.1.4 Sensor Extension Cables at the ECU
On valves that are tank mounted with no trailer structure nearby, or have remote-mounted cables, the sen-
sor extension cables are attached to the air lines. Cable clips are preferred over zip ties. It is important to
remember that cables should be fastened in a manner where the cable is secured enough where the cable
will not move or chafe against what it is mounted to. A small amount of slack should be present to ensure
that the cables do not become taut after installation or the servicing of components. Figure 21 illustrates
the correct amount of slack in the sensor extension cables and correct attachment to the air delivery lines
for ABS ECUs.
Fig. 21
4"
Max.
12"
4"
Max.
12"
FASTENER
FASTENER
ZIP TIE
ZIP TIE
SENSOR EXTENSION CABLES - ECU FRONT VIEW
4014394c