19
Introduction
The values must fall within the following restrictions:
Valid range: 5-100 psi
Lowering Pressure must be greater than Lifting Pressure
Lowering and Lifting pressures must di
ff
er by at least 15 psi
6. The values are validated and programmed when the
OK
button is pressed. When a con
fi
rmation
message appears, press the
OK
button to continue. Figure 13.
Fig. 13
4017332a
7. After selecting
OK
on the Lift/Lowering Pressures window, it will go back to the
GIO Con
fi
guration
Window, and the ECU will reset 2 times. Once the resets are complete, a Download Complete window
will pop up. Click
OK
and the programming is now
fi
nished. Figure 14.
Fig. 14
4017333a