Page 8 of 34
PQ-132-U
2.2 Compatibility
As a result of further developments some smaller changes have to be taken in consideration.
Functionality
:
1. Downward compatible to the older modules.
2. 100 % wiring compatible.
3.
Baud rate
: The default baud rate has changed from 9600 baud to 57600 baud. This is adaptable in
WPC-300: OPTIONS/SETTINGS/INTERFACE.
FIXBAUDRATE = 57600 and/or AUTO BAUDRATE DETECTION = 57600
4. Technical enhancements:
a. Programmable analogue output: only one version (U instead A and I) is necessary
b. Double parameter set selectable via a command and input pin 5
c. current loop input for the Q - value
Parameterization
:
1. Standardizing of parameter names
2. Simplified and intuitive parameterization of the analogue inputs and sensors
3. Compatibility mode of the input scaling (
AINMODE
), if necessary
4. Adaptation of the output signal (current or voltages) and the polarity with the command
SIGNAL:U
(the
POL
commando is removed)