16 TROUBLESHOOTING
If the device is not working
You should check if:
1.
There is not an electrical supply failure?
2.
The power cord is plugged in the mains socket properly?
3.
The fuse has not been blown?
4.
The power cord has not been damaged?
Cooling systems is not effective.
1.
What is the temperature outside the device?
2.
Is the door shut tight?
3.
Is the condenser clean?
4.
Is the device placed in direct sunlight?
5.
Is there any heat source near the device?
6.
Are there too many objects inside the device that are not cool enough?
Water is condensing inside the chamber
1.
Is the defrosted water outlet not blocked?
Frost occurs on walls:
1.
Usual condition while working in low temperatures.
The device is operating too loud
1.
Is the device not leaning against furniture or other objects?
2.
Are the pipes at the back in direct contact or are they vibrating?
3.
Is the device leveled properly?
CAUTION: Buzz and noise from decompression coming from the cooling circuit are
normal noises.