Page 17
SYMPTOM
POSSIBLE SOLUTION
Unit never locks on or locks on
and drifts off of satellite.
Atmospheric moisture. Unit will lock on as weather improves.
Check for obstruction in sky in direction of satellite. Select another satellite
and verify unit locks on.
Verify coax cables are properly terminated with
SNAP-N-SEAL
®
connectors only.
Perform
OPTION 21 RE-INITIALIZE and 0-RECALIBRATE
(pages 18-19).
Inspect all coax cables for kinks and verify connections are snug but not
overly tight.
Perform
Temperature Calibration (CALL KING CONTROLS FIRST).
Check for line of sight obstruction.
Check for low signal strength.
Current location might be out of service area.
Select alternate trio of satellites (SW64) and try again.
Atmospheric moisture. Wait for weather to improve.
Can’t get SW21 or SW 64
switch to load properly.