Gear Reducer Orientation and Lubrication
It is important to always maintain an adequate level of gear oil for the size and
orientation of the reducer. Unless otherwise specified, the reducer is filled for
horizontal use. Consult the maintenance section for recommended gear oil types
and amounts.
WARNING
Low oil level may result in premature wear of the gears. Consult the
maintenance section for the recommended oil types and amounts.
The reducer is always shipped with standard plugs to prevent oil from leaking
during transportation. The client must install the vent plug according to the
reducer orientation before putting the winch into service. The vent plug is
supplied in a plastic bag taped to the reducer.
Symbol
Definition
Vent plug
Level plug
Drain plug
*make sure the vent plug is
always on the top side to
ensure no leakage during the
use or the transportation of
the equipment
WARNING
Failure to install the vent plug may result in pressure built-up as the
reducer heats up causing the seals the blow out and spill the oil.