background image

– 8 –

CLEANING (DAILY)

Allow broiler to cool.

Thoroughly scrape grill so that grease flows into grease drawer.  This prevents flare-ups.

Soak grill overnight and rinse.

Remove and empty grease drawer.  Wash, rinse, and dry with a soft clean cloth.  Once broiler is clean,
replace grease drawer.

Clean stainless steel surfaces with a mild detergent and water, using a damp cloth, or with a
commercial stainless steel cleaner.  Rinse thoroughly and wipe dry with a soft clean cloth.

Burner ports and throats should be thoroughly cleaned.  Venturi must be free from grease and lint.  DO
NOT
 insert pick in burner port hole.

MAINTENANCE

WARNING:  THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING,
CLEANING OR SERVICING THE BROILER.

LUBRICATION

All moving parts must be checked for wear and lubricated.  Contact your local Vulcan authorized
servicer.

PILOT LIGHTS

Pilot lights are to be kept clean and adjusted at the proper flame height.

VENT

Annually, when the broiler is cool, check the flue and clear any obstructions.

RECOMMENDED SERVICE FREQUENCY

Frequency of service maintenance will be largely dependent upon customer usage.

10-12 hours operation per day, 7 days a week

Every 30-60 days

4-6 hours a day, 5 days a week

Every 120 days

Limited daily usage

Every 180 days

All equipment

At least once a year

SERVICE AND PARTS INFORMATION

To obtain service and parts information concerning this broiler, contact the Vulcan-Hart Service
Agency in your area (refer to listing supplied with the broiler), or Vulcan-Hart Company Service
Department at the address or phone number shown on the front cover of this manual.

FORM 31168 (Jan. 2001)

PRINTED IN U.S.A.

Содержание VRB Series

Страница 1: ...ML 44960Z VRB36FC ML 44957Z VRB36FS ML 44958Z VIR36 ML 44947Z VIR36C ML 44948Z VIR36M ML 44961Z VIR36S ML 44949Z VIR36F ML 44950Z VIR36FM ML 44962Z VIR36FC ML 44951Z VIR36FS ML 44952Z INSTALLATION OPE...

Страница 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Страница 3: ...ng the Gas Supply System 6 Flue Connections 6 OPERATION 7 Controls 7 Lighting Instructions 7 Grid Position and Gas Setting 7 Preheating 7 Operating VRB36 Series Models 7 Operating VIR36 Series Models...

Страница 4: ...leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the broi...

Страница 5: ...obicoke Ontario Canada M9W 1R3 LEVELING Place a carpenter s level inside the broiler Level the broiler front to back and side to side Unless the broiler is level it will not give proper cooking result...

Страница 6: ...remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds 1 2 psig 3 45 kPa the broiler and its individual shutoff valve must be disconnected from the gas supply piping system When ga...

Страница 7: ...4 To relight follow steps 1 3 GRID POSITION AND GAS SETTING Each operator will find the optimum grid position and gas setting for various products however it is recommended that gas input be reduced...

Страница 8: ...LUBRICATION All moving parts must be checked for wear and lubricated Contact your local Vulcan authorized servicer PILOT LIGHTS Pilot lights are to be kept clean and adjusted at the proper flame heigh...

Отзывы: