– 7 –

OPERATION

WARNING:  THE BROILER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING,
CLEANING OR SERVICING THE BROILER.

CONTROLS

Gas Valves

— Regulate gas flow to the burners.

Elevator Lever

— Use elevator lever on the right to position the grill in relation to the burner heat.

Grease Drawer — Collects grease from broiled food.

LIGHTING INSTRUCTIONS

1.

Turn the gas shut-off and gas valves to the OFF position and wait 5 minutes.

2.

Turn gas shut-off valve ON and light two pilots with a lit taper. Adjust until the pilot flame is 

1

/

4

"

(6 mm) high.  The flame should have a slight yellow tip.  Pilot valves are behind the plug button
on the right panel.

3.

The only adjustment needed may be the air shutter located at the front face of the burner where

the orifice enters the venturi. Adjust all traces of yellow out of the burner flame.

4.

To relight, follow steps 1-3.

GRID POSITION AND GAS SETTING

Each operator will find the optimum grid position and gas setting for various products; however, it is
recommended that gas input be reduced first when lower grid temperatures are desired.  Further
reduction in grid temperatures, if necessary, can then be adjusted by lowering the grid position.

PREHEATING

Allow broiler to preheat approximately 30 minutes with burners full-on.  Rub grates with grease before
using.  The excess grease will run forward and drip onto the front grease drawer.

OPERATING VRB36 SERIES MODELS

1.

Load broiler.

2.

Turn gas valve to the left (counterclockwise) as far as the knob will go.

3.

When the burner lights, turn the knob to the right (clockwise) until the flame is the desired height.

OPERATING VIR36 SERIES MODELS

1.

Turn valves full ON to light.

2.

Do not adjust lower than one-half flame.

SHUTDOWN

1.

For complete shutdown, turn gas and shut-off valves to the OFF position.

2.

Turn pilot adjustment valve fully closed until gas stops flowing.

Содержание VRB Series

Страница 1: ...ML 44960Z VRB36FC ML 44957Z VRB36FS ML 44958Z VIR36 ML 44947Z VIR36C ML 44948Z VIR36M ML 44961Z VIR36S ML 44949Z VIR36F ML 44950Z VIR36FM ML 44962Z VIR36FC ML 44951Z VIR36FS ML 44952Z INSTALLATION OPE...

Страница 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Страница 3: ...ng the Gas Supply System 6 Flue Connections 6 OPERATION 7 Controls 7 Lighting Instructions 7 Grid Position and Gas Setting 7 Preheating 7 Operating VRB36 Series Models 7 Operating VIR36 Series Models...

Страница 4: ...leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the broi...

Страница 5: ...obicoke Ontario Canada M9W 1R3 LEVELING Place a carpenter s level inside the broiler Level the broiler front to back and side to side Unless the broiler is level it will not give proper cooking result...

Страница 6: ...remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds 1 2 psig 3 45 kPa the broiler and its individual shutoff valve must be disconnected from the gas supply piping system When ga...

Страница 7: ...4 To relight follow steps 1 3 GRID POSITION AND GAS SETTING Each operator will find the optimum grid position and gas setting for various products however it is recommended that gas input be reduced...

Страница 8: ...LUBRICATION All moving parts must be checked for wear and lubricated Contact your local Vulcan authorized servicer PILOT LIGHTS Pilot lights are to be kept clean and adjusted at the proper flame heigh...

Отзывы: