SOLID STATE TEMPERATURE
CONTROL TEST
Certain procedures in
this section require electrical test or
measurements while power is applied
to the machine. Exercise extreme
caution at all times and follow Arc Flash
procedures. If test points are not easily
accessible, disconnect power and
follow Lockout/Tagout procedures,
attach test equipment and reapply
power to test.
1.
Remove RIGHT SIDE FRONT PANEL.
NOTE:
If right side panel is not accessible, this
component can be serviced by removing CONTROL
PANEL.
2.
Place a thermocouple in the geometric center of
oven cavity.
NOTE:
Oven temperature must be below 450°F.
3.
Set the temperature control to the maximum
setting.
4.
The green indicator light will flash once every 3
seconds if the board is receiving power. If it is off
the problem is not with the Temperature Control
Board. Refer to" TROUBLESHOOTING.
5.
If the red fault indicator comes on count the
number of times it flashes and check
TEMPERATURE CONTROL BOARD FAULT
INDICATOR table to identify fault code.
TEMPERATURE CONTROL BOARD FAULT INDICATOR
Certain procedures in this section require electrical test or measurements while
power is applied to the machine. Exercise extreme caution at all times and follow Arc Flash
procedures. If test points are not easily accessible, disconnect power and follow Lockout/Tagout
procedures, attach test equipment and reapply power to test.
Code
Description
Action
1
Open Probe
Verify probe is plugged in. Replace
2
Shorted Probe
Replace TEMPERATURE PROBE.
3
No Heat
4
PCB Overheat
Verify cooling fan works. Clean air
intake at back of oven.
5
No Output
Replace temperature control PCB.
6
Output Shorted
Replace temperature control PCB.
VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - SERVICE PROCEDURES AND ADJUSTMENTS
Page 15 of 31