4
Installation, Operation, and Care of
GAS COMBI STEAM & CONVECTION OVENS
KEEP THIS MANUAL FOR FUTURE USE
GENERAL
The Gas Combi Steam & Convection Ovens are single compartment ovens that provide steam and/
or convection heating. Various models can handle
10
or
20
shelves,
F
ull or
H
alf depth. A
P
rogrammable control is provided on all size/depth combinations. The
bold
numbers and letters
explain the model-number conventions. An atmospheric steam generator can provide humidification
in the oven chamber.
The 10 level models can be installed on an optional table or on a suitable countertop using the legs,
provided. Trolleys or landing tables (depending on size of oven) can load or unload all racks in one
easy motion. The hose spray accessory can be installed near the oven to facilitate easy cleaning.
INSTALLATION
UNPACKING
Immediately after unpacking the oven, check for possible shipping damage. If the oven is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, verify that the electrical service and type of gas (natural or propane) agree with the
specifications on the oven data plate.
LOCATION
Allow space for operating the oven. Do not obstruct the ventilation ports above the oven. Do not install
the oven next to a major heat source, such as a griddle or fryer. All models require a minimum clearance
of 8" on the right side of the oven and 6" at the rear. The 8" clearance on the right side also provides
room for the gas connection. Additionally, model VC10FGP requires an 8" clearance on the left side.
LEGS
(Provided for 10 Shelf Models)
Screw feet into legs at four corners and set oven on suitable countertop.
TABLE
(Optional for 10 Shelf Models)
To assemble the oven onto the caster equipped table, insert four bolts from
underneath at the four corners and tighten until secure.
CONDENSATE GUTTER
Loosen screws under front of oven base and assemble condensate gutter to
bottom of oven. The 20 level ovens have a three segment condensate gutter and
dual input drain tube. Connect tube (if provided) to condensate gutter and drain.
NOTE
: The 20 level gas ovens are equipped with casters, preassembled on the bottom of the oven.
LEVELING
The oven must be placed in a level location. Using a spirit level or pan of water in the bottom of the
oven, make sure the oven is level, both front-to-back and side-to-side. After the drain is connected
(page 7), check for level by pouring water onto the floor of the compartment. All water should drain
through the drain opening.
Tube
Condensate Gutter
Oven
Door
To Drain