Vulcan-Hart 019-4274 Скачать руководство пользователя страница 4

4

switch does not turn it on and off properly.

User service.

 Some user-serviceable components 

are described in the Troubleshooting section. We 

cannot guarantee repairs made or attempted by 

anyone other than authorized agencies.

Tool service must be performed only by 

qualified repair personnel.

 Service or 

maintenance performed by unqualified personnel 

could result in risk of injury. For example, internal 

wires may be misplaced or pinched, safety guard 

Guard against electric shock.

 Prevent body 

contact with grounded surfaces: pipes, radiators, 

ranges, and refrigerator enclosures. Before 

driving fasteners into walls, floors, or wherever 

“live” electrical wires may be encountered, try to 

ascertain whether there is a danger of shock.

Hearing protection.

 Wear ear protection when 

using the tool for extended periods. Prolonged 

exposure  to high intensity noise can cause 

hearing loss.

Safety glasses 

To prevent eye injuries, the tool 

operator and all persons in the work area must 

wear approved safety glasses conforming to ANSI 

Z87.1 specifications with permanently attached, 

rigid side shields.

Use clean, dry, regulated, compressed air 

at 70 

to 120 psi.

Do not connect tool to pressure which 

potentially exceeds 200 psi.
Air hose.

 Only use hose that is rated for a 

minimum working pressure of 150 psi or 150% 

of the maximum system pressure, whichever is 

greater.

Never use oxygen, carbon dioxide, combustible 

gases or any other bottled gas as a power 

source for this tool.

 Explosion and serious 

personal injury could result.

Couplings.

 Connect tool to the air supply hose 

with 1/4” NPT couplings that remove all pressure 

from the tool when the coupling is disconnnected.

Be aware of air hoses and their connections. 

Don’t trip over hoses. Make sure all connections 

are tight.

 

Disconnect tool from air supply hose before 

return springs may be improperly mounted.

When servicing tool, use only identical 

replacement parts.

  Follow instructions in 

the Maintenance section of this manual. Use 

of unauthorized parts or failure to follow 

Maintenance instructions may create a risk of 

injury. Certain cleaning agents such as gasoline, 

carbon tetrachloride, ammonia, etc. may damage 

plastic parts.

SAFETY RULES FOR AIR NAILERS

doing any disassembly, maintenance, loading 

fasteners, clearing a jammed fastener

, leaving 

the work area, moving the tool to another 

location, or handing the tool to another person.

Never use a tool that is leaking air, has missing 

or damaged parts, or requires repair.

 Before 

each use, make sure all screws and caps are 

securely tightened.

Check for damaged parts.

 Never use a tool if 

safety, trigger, or spring are inoperable, missing or 

damaged. Do not alter or remove safety, trigger, 

or springs. Make daily inspections for the free 

movement of trigger and safety mechanism.

Replacement parts

. When servicing, use 

only identical replacement parts and fasteners 

recommended by us.

Be sure the tool is disconnected from the air 

supply before loading the fasteners. 

Take 

care on re-connection: fasteners may be fired 

accidentally during connection. The fastener 

driving mechanism may cycle when the tool is 

connected to the air supply.

Assume the tool contains fasteners at all times.

 

Always keep it pointed away from yourself and 

others. No horseplay. Respect the tool as having 

lethal potential.

Do not load fasteners with trigger or safety 

depressed.

 The tool may unintentionally fire a 

fastener.

Do not depress the trigger unless the nosepiece 

is directed at the worksurface or when not 

driving fasteners. 

Never carry tool with finger on 

or touching the trigger mechanism: tool may fire 

an unwanted fastener.

Содержание 019-4274

Страница 1: ...Instruction Manual Manual de instrucciones ITEM NO 019 4274 ARTICULO No OFNC1590 000 0000 v070820 15o Framing Coil Nailer...

Страница 2: ...o material and workmanship for a period of ONE YEAR from date of purchase If defective the product will be repaired or replaced Call the Vulcan Power Tool customer service line at 1 800 482 0131 and a...

Страница 3: ...ctrical wires may be encountered try to ascertain whether there is a danger of shock Do not overreach Keep proper footing and balance at all times Do not reach over or across machines which are runnin...

Страница 4: ...tions Don t trip over hoses Make sure all connections are tight Disconnect tool from air supply hose before return springs may be improperly mounted When servicing tool use only identical replacement...

Страница 5: ...rate Grip tool firmly to maintain control while allowing the tool to recoil away from the work surface as the fastener is driven If the safety is allowed to recontact the work surface before the trigg...

Страница 6: ...e selector E Trigger F Male quick connect fitting SPECIFICATIONS Operating pressure 70 120 psi max 120 psi Air consumption 0 17 cu ft cycle 100 psi Air Inlet 1 4 NPT Weight 8 2 lbs Pkg weight 15 4 lbs...

Страница 7: ...ft is ideal All compressed air contains moisture and other contaminates that are detrimental to internal components of the tool An airline filter will remove most of these contaminates and significan...

Страница 8: ...een minimum and maximum adjust the lower magzine accordingly 7 Close the lower magazine 2 Depress cover plate latch L fig 3 CAUTION Disconnect the tool from the air supply Keep tool pointed away from...

Страница 9: ...ing surface Once the bracket is pushed back enough the nail will fire Original factory setting is single sequential fire mode READ and UNDERSTAND this operating manual before changing trigger mode Im...

Страница 10: ...djust the safety bracket upward Test fire another fastener in a scrap work piece and check the depth REPEAT AS NECESSARY UNTIL DESIRED DEPTH IS ACHIEVED The amount of air pressure required will vary d...

Страница 11: ...cause accelerated wear on the seals Check the filter of the compressor weekly Open drain cock to drain all water and contaminants out of the air tank Wipe the tool clean Blow the tool clean using hig...

Страница 12: ...the contact between bumper and body Disassemble clean Air leaking from the upper body and the nose Screw is loose at connection between cylinder and body Tighten screw re check O ring is damaged Chec...

Страница 13: ...rDamaged pusher spring Disassemble clean lubricate O ring on the small piston is worn and damaged Check replace O ring lubricate Tool dry lack of lubrication Use pneumatic tool oil Spring on the small...

Страница 14: ...cap damaged Replace spring in the cylinder cap Foreign matter between the piston assembly and cylinder Disassemble clean lubricate Cylinder is not assembled to home position Reassemble after disassem...

Страница 15: ...O Ring 67 X 3 24 Restrictive Seal 25 O Ring 97 5 X 3 5 26 Bumper 27 Bumper 28 Body No DESCRIPTION 29 O Ring 30 Guide Washer 31 Nose 32 Spring Washer 33 Screw 34 Spring 35 Bracket Assembly 36 Adjuster...

Страница 16: ...65 O Ring 28 3 X 3 66 Piston 67 Torsion Spring 68 Pin 69 Feed Hook 70 O Ring 14 3 X 2 5 71 Screw 72 Pin 73 Plate 74 Protector 75 Protector 76 Pin 77 Stop Hook 78 Taper Spring 79 Screw No DESCRIPTION 8...

Страница 17: ...17 SCHEMATIC DRAWING...

Отзывы: