www.vtdrive.com
25
cut off the power to stop running.
●
If the soft starter starts badly , you can check whether the starting mode you
choose is fit for your motor . Please see the detailed explanation at 7.2: the
starting mode and application
●
If the Moment of starting is not strong enough , you can change the starting
voltage (when the starting mode is voltage control) or the limit-current value (when
the mode is current control) to strength the Moment of starting .
●
Do not open the up-cover in case of electricity .
●
If there is any abnormal voice, smoke or taste , is very important for you to cut
off electricity as soon as fast , and check the reasons .
●
When the starter is in electricity or is starting , the Fault-lamp is lighting and
screen displays” Err××", at this time , you had better check the Form 7.1 to get the
reason .
Note : When the temperature round is less than -10
℃
, the starter should be
preheated for 30 minute with electricity , and then start .
Faults and Solution way (Form 7.1)