14
time”
P2
This code is used
to set the “soft
starting
time”
0-60S
0S
If the code is set as “0”,the
motor will “staring mode”
P3
This code is used
to set the time of“
start-up time delay”
0-999S
0S
By the count-down way, If set as
“0”, the starter will start up the
motor Immediately without
time-delay.
P4
This code is used
to
time of
“programming
output
time-delay”
0-999S
0S
Be used with” programming
relay output”
P5
This code is used
to
set the “Interval
start
time-delay”
0-999S
0S
Be used when you need or have
to
Re-start the motor for several
times, or Re-start the motor after
removing the over-heat protection
for motor.
P6
This code is used
to
set the “start-up
limit
current value”
50-500%
280%
It is used when the staring mode
is “Limit-current”, and the value
will be fixed as 400% when the
starting mode is” Ramp voltage to
start”