background image

 

FRSky, Version: 1.4 

www.VSpeak-modell.de

 

Page 16/16 

12

 

EG Declaration of Conformity 

Manufacturer 

VSpeak-Modellbau (Volker Weigt) 
Priestewitz 

We hereby declare that the product 

Speech module VSpeak 

complies with the following European directives: 

2004/108/EC 

EMC Directive 

2006/95/EC 

Low Voltage Directive (LVD) 

2011/65/EC 

Restriction of Hazardous Substances (RoHS) 

The presumption of conformity is taken by applying the following harmonized standards: 

EN60065 

Audio-, video- and similar electronic aparatus - Safety requirements 

EN60332 

Tests on electric and optical fibre cables under fire conditions 

EN60950 

Information technology equipment - Safety 

EN61000-6-1 

Electromagnetic compatibility (EMC) 

EN61000-6-3 
EN55022 

Information technology equipment - Radio disturbance characteristics 

 
 

Priestewitz, 2012/06/01 

 .................................................  

13

 

Version history 

Vers.-No 

Date 

Comment 

1.0 

06.2012 

First retail version 

1.1 

11.2012 

Adjustment to changed accuracy of current measurement (FAS-100) 
Support of the "VSpeak-Vario" 
new voices in Czech and Russian

 

1.2 

01.2013 

Correction voltage, power, power consumption (FAS-…)

 

1.3 

09.2013 

Correction of occasional erroneous announcements (altitude, 
total cell voltage, at logging of theVSpeak Vario) 
Correction announcement RX link quality indicator in dbm 
new voices in portuguese, italian, dutch and hungarian 

1.4 

01.2015 

Altitude and capacity difference triggered announcement is possible 
Support for 3 different parameter sets

 

14

 

Contact 

Volker Weigt 

www.VSpeak-modell.de 

mail: 

[email protected]

 

Signature 

Volker Weigt 

Managing Director 

Содержание VSpeak for FRSky

Страница 1: ...Hub System V2 0 compatible sensors on the receiver side to be transfered and transmitted as voice on the radio side Both protocols are disclosed by FRSky www frsky rc com In the realization of the mo...

Страница 2: ...8 Supported sensors 12 8 1 Telemetry Receiver D series and S Port Telemetry X series 12 8 1 1 analog inputs A1 A2 Volt ratio 12 8 1 2 analog inputs A1 A2 Alarm Set 12 8 2 Sensor Hub V2 0 and Sensors...

Страница 3: ...transmitter module The speech module must NOT directly be plugged into the DHT DFT DJT XJT module as this might damage both the DHT DFT DJT XJT module and the speech module For the operation the FrSky...

Страница 4: ...y thus so NO connection for the speech output module VSpeak is available yet 2 4 Communication If properly installed the speech module does not affect the functionality of the transmission system The...

Страница 5: ...FrSky These are all acoustically given by a beeper Two2 alarms each for A1 and A2 and for Rx and Tx can be set in the Menu Screen of the FLD 02 The alarm level can also be selected Alarm Set Level Mea...

Страница 6: ...ing ON OFF Vario sensitivity 1 2 3 8 9 1 highest 9 lowest sensitivity with connected Vspeak Vario 1 2 3 complies 0 1 m s 4 5 6 complies 0 2 m s 7 8 9 complies 0 3 m s Vario sound volume 1 2 3 15 16 15...

Страница 7: ...t During the announcement of the setting parameters gray background the setup can be cancelled by pressing the key The changes made until the abortion will be saved Table settings No Setting parameter...

Страница 8: ...actual max OFF 32 blade number 10 0 10 20 90 33 blade number 1 0 1 2 9 34 announcement speed min actual max OFF 35 speed in km h mph 36 announcement voltage in V min actual max OFF 37 announcement cur...

Страница 9: ...et for the interval time in seconds 5 10 15 20 25 30 40 50 60 To 9 10 13 14 For the analog values 1 and 2 respectively the following units may be selected for the announcement V A 1 min C F m s mph km...

Страница 10: ...in 16 steps in its volume While setting a tone is generated which corresponds to the least falling To 32 33 blade number Blade 02 blade number 10 0 No 32 tens blade number 1 2 No 33 one To 36 announc...

Страница 11: ...untry code e g DE for German and voices e g Robbi Rolf Silvia The directory XYZ is available in any language The available wav files can be replaced by diligent users of the Vspeak module by own recor...

Страница 12: ...times of 3 3 V Thus by a Voltage ratio for A1 the value of 4 is to be set for the speech module VSpeak according to the table in section 5 3 no 11 12 8 1 2 analog inputs A1 A2 Alarm Set For the analog...

Страница 13: ...io sound 8 2 6 GPS 01 GPS Announcement speed in kmh mph 8 2 7 RPMS 01 RPM Sensor Announcement rotation speed in rpm 8 2 8 TAS 01 Triaxial Acceleration Sensor Announcement acceleration X axis in g Anno...

Страница 14: ...there is no information of the climb rate at the output of the FrSky Transmit Modules DHT DFT The VSpeak module generates the vario tone by a calculation based on the altitude This is not the best way...

Страница 15: ...e BT transmitter functions with just about every BT headsets except those devices specified in the manual mobile phone accessories Note In order to enable the B SPEECH TX2 in pairing mode hold down th...

Страница 16: ...compatibility EMC EN61000 6 3 EN55022 Information technology equipment Radio disturbance characteristics Priestewitz 2012 06 01 13 Version history Vers No Date Comment 1 0 06 2012 First retail version...

Отзывы: