VS DATAGAUSS LG ZZ201207 Скачать руководство пользователя страница 2

 

VS Security Products LTD

 

ZZ201207, ZZ201208, ZZ201209, ZZ201211, ZZ201212, ZZ201213

 

 Page 2 of 30

 

 

VS SECURITY PRODUCTS LTD

 

 

DATAGAUSS LG

 

DATAGAUSS XL

-

LG

 

Hard drive degausser

 

 

OPERATING MANUAL

 

production standard

 

 

Datagauss lg ZZ201207 

-

 230v 50Hz

 

Datagauss lg ZZ201208 

-

 115v 60Hz

 

Datagauss lg ZZ201209 

-

 220v 60Hz

 

Datagauss xl

-

lg ZZ201211 

-

 230v 50Hz

 

Datagauss xl

-

lg ZZ201212 

-

 115v 60Hz

 

Datagauss xl

-

lg ZZ201213 

-

 220v 60Hz

 

 

 

 

WARNING

 

 

to  avoid  electric  shock  hazards,  the  cover  should  only  be  removed  by  authorised 

personnel

 

 

SAFETY RECOMMENDATIONS

 

It is recommended that people with any form of heart pace

-

makers or implants etc. avoid 

close  proximity  to  any  equipment  of  this  type  without  first  seeking  appropriate  medical 

advice.

 

 

Operators of the Degausser should ensure they remove any wrist watches prior to using the unit, 

and that any credit cards or other magnetic devices are placed out of range.

 

 

CAUTION

 

it is  recommended  that magnetic storage media  is kept  at least 

1

  metre 

(3 Feet)

  from  the 

degausser

 

 

IMPORTANT

 

the  power  on/off  switch  used  on  this  equipment  is  not  an  isolating  switch.    it  is 

recommended that this equipment should be operated from a separate switched isolator.

 

 

COPYRIGHT

 

This document is the property of VS Security Products Ltd and it may not be reproduced, 

copied  or  exhibited  to  a  third  party  without  the  written  permission  of  VS  Security 

Products Ltd.

 

 

 

 

VS SECURITY PRODUCTS LIMITED

 

Unit 17, Pegasus Court

 

North Lane

 

Aldershot

 

Hampshire 

-

 GU12 4QP

 

United Kingdom

 

 

 

Tel:

 

+44 (0) 1252 333577

 

Fax:

 

+44 (0) 1252 333448

 

Email: [email protected]

 

VS AND ASSOCIATES

 

3160 Texas Hill Road

 

Placerville

 

California

 

95667

 

United States of America

 

 

Tel:   530

-

626

-

6924

 

Fax:  530

-

626

-

6989

 

Email: [email protected]

 

Содержание DATAGAUSS LG ZZ201207

Страница 1: ...ZZ201207 ZZ201208 ZZ201209 ZZ201211 ZZ201212 ZZ201213 Rev 12...

Страница 2: ...hey remove any wrist watches prior to using the unit and that any credit cards or other magnetic devices are placed out of range CAUTION it is recommended that magnetic storage media is kept at least...

Страница 3: ...ar purpose and non infringement SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU YOU MAY ALSO HAVE OTHER LEGAL RIGHTS WHICH VARY FROM JUR...

Страница 4: ...atagauss LG XL LG Degaussers 6 5 Software Installation 6 6 Operation Guide 9 7 Erasure Logger Software 11 8 Interrogating the Database 16 9 Printing Records 17 10 Supervisor Screen 19 11 Safety Recomm...

Страница 5: ...E 5 C 41 F to 40 C 104 F HUMIDITY 10 to 80 non condensing MOUNTING Free standing table top DIMENSIONS DataGauss LG 13 9 x 9 2 x 14 3 35cm x 23cm x 36cm DataGauss XL LG 13 9 x 9 7 x 14 3 35cm x 24 6cm...

Страница 6: ...e it from the packing box 3 2 Power Wiring Power connection is made to the Datagauss degausser in the form of an IEC type electrical lead supplied The user should ensure that their power supply meets...

Страница 7: ...201211 ZZ201212 ZZ201213 Page 7 of 30 Close all Windows programs that are running and click NEXT Tick the box to confirm you have read and accept the software licence conditions and click NEXT Check t...

Страница 8: ...ts LTD ZZ201207 ZZ201208 ZZ201209 ZZ201211 ZZ201212 ZZ201213 Page 8 of 30 Select the number of Users and click NEXT Click NEXT to start the installation Click FINISH to complete the installation of th...

Страница 9: ...moved The entire process takes just 45 seconds Throughout the whole cycle the onboard processor monitors the erase procedure ensuring that it is completed correctly The operator is immediately alerted...

Страница 10: ...up the data entry if required When the logging program has been opened on the PC and the DataGauss is connected the operator simply clicks on the Find Machine button for all the unit details to be au...

Страница 11: ...edia destruction is completed It is possible to interrogate the database to retrieve the destruction information record This record or a number of records can be printed out using any printer attached...

Страница 12: ...nternet or is running Windows XP then it will be necessary to install the USB drivers manually If you received a CDROM installation disc from VSSP the FDTI USB drivers and installation instructions ar...

Страница 13: ...Owner panel can be used to clear all the entries in the panel if required 7 3 1 Bar Code Scanner If the bar code scanner has been installed it can be used to enter bar code data such as serial number...

Страница 14: ...elevant data boxes have entries destruction will commence and the following screen is displayed When the destruction process has completed the destruction data is shown in the Media Processed box The...

Страница 15: ...abel print job to the Windows Print Spooler the Windows Print Spooler is responsible for sending the print Data to the selected printer If the selected printer is switched off or disconnected there is...

Страница 16: ...The above can be repeated for each record that is to be viewed 8 2 Resuming Destruction after Interrogation When the database records are being interrogated the DESTROY button is disabled To enable th...

Страница 17: ...nter Page 1 20 06 2014 14 31 28 Media Destruction Record Company Name VSSP Operator Victoria Supervisor Brian Degaussing on Site Yes Media Owner Company Name ICL Engineering Department Engineering Med...

Страница 18: ...he Control Ctrl key down and click the individual records to be printed When you have selected the records to be printed click the Print button the normal print dialog box will be displayed Select the...

Страница 19: ...be displayed To enter the Supervisor screen the correct password must be entered The default password is password Note that this is all lower case The password can be changed in the supervisor screen...

Страница 20: ...e Logger main Screen This allows the supervisor to specify exactly which Data Entry Boxes are to be displayed on the Logger main screen On the Mandatory sub panel a tick box with a tick in it will cau...

Страница 21: ...Password button 10 4 Printer Line Spacing The Printer Line Spacing setting allows the lines on the printed records to be adjusted If the lines on the printer are too close together increase the value...

Страница 22: ...lect Printer Button This will cause the Windows Print Setup box to be displayed Select the required printer from the list and click OK NOTE The label print application is designed to work with a Broth...

Страница 23: ...he print job will sit in the Windows Print Spooler Queue until the selected printer becomes available At this point the print job is printed as are any other queued print jobs Logo Offset The logo off...

Страница 24: ...rd Windows Save File dialog box The supervisor can then choose a location e g drive and or folder to store the archive file The supervisor can also name the file as required The file name can be defin...

Страница 25: ...ia Info Capacity 18 Media Info PN 19 Media Info Class 20 Media Info Remarks 21 Capacitor Voltage Volts 22 Magnetic Field Strength Gauss 23 Result Degaussed Crushed Failed etc Field number 01 is the fi...

Страница 26: ...cluding the label printer name and the database file name NOTE Do not change the contents of the ini file the logger application may become unusable 10 6 4 Moving the Database The storage location and...

Страница 27: ...on This displays the windows save as dialog navigate to the directory you wish to save the database file in Enter the required name for the database and click save The below dialog box shows the name...

Страница 28: ...Linux based server on the network it uses the SMB File sharing protocols to allow Windows Sharing The below database screen shows that the database has been created in the network location QNAP 1 Tes...

Страница 29: ...re placed out of range SECTION 12 MAINTENANCE 12 1 Resetting the circuit breaker The DataGauss Degasser is not equipped with any on board fuses that require replacement All the systems within the unit...

Страница 30: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA...

Отзывы: