6.1.1 Erasure of Hard Drives and Large Backup tapes LTO, DLT, 3480 series.

 

 

1.

 

Connect the unit to the power supply

 

2.

 

Activate the power switch on the rear of the unit.

 

3.

 

Once the unit is ready, gently slide the lid release lever rearwards and allow the lid to hinge up. Place the hard drive 

into the chamber, and latch down the lid.

 

 

NOTE:  Hard  drives  are  manufactured with  the  disc  mounted  at  one  end  of  the  assembly,  the  hard  drive  must  be 

placed  in  the  cavity  effectively  on  its  edge.  If  this  is  not  observed  the  lid  will

 

not  latch  down.  Under  no 

circumstances should excessive force be used to close the lid.

 

 

4.

 

Once the lid is latched down the erase cycle is initiated by operation of the erase button. When the erase cycle is 

 

complete, as indicated on the display, the lid may be unlatched and the media removed.

 

 

 

6.1.2 Erasure of 

2.5” & 1.8” 

Hard Drives and small media 4mm and 8mm cassettes etc.

 

 

To erase small hard drives 

2.5” & 1.8” 

and also small media 4mm and 8mm cassettes etc., they should be placed in the 

Small Media Carrier supplied with your DataGauss.

 

 

1.

 

Connect the unit to the power supply

 

2.

 

Once the unit is ready, gently slide the lid release lever rearwards and allow the lid to hinge up. Place the carrier into 

the cavity and latch down the lid.

 

3.

 

Once the lid is latched down the erase cycle is initiated by operation of the erase button. When the erase cycle is 

complete, as indicated on the display, the lid may be unlatched and the carrier removed. 

 

 

6.2 Operation with Erasure Logging

 

 

Operation

 

 

When erasure logging is required, simply connect the degausser to a PC or laptop and open the logging program. This will 

log all the information related to the erasure and provide a printed report if required. The information logged includes 

 

details 

of the degaussing company (including the operator and supervisor), media owner, degausser machine type, serial number, 

part number and size of the Hard Drive or Tape. 

 

 

Information is entered onto the software via keyboard or optional barcode scanner to speed up the data entry, if required. 

When the logging program has been opened on the PC and the DataGauss is connected, the operator simply 

 

clicks  on  the 

Find  Machine

” 

button  for  all  the  unit  details  to  be  automatically  entered  into  the  log  including  model,  serial  number  and 

firmware version. The DataGauss display will show it is in remote mode controlled by the PC.

 

 

Further data regarding operator, customer and media is then entered via keyboard (or optional barcode scanner) before the 

Hard Drive or Tape is placed into the degausser and the lid closed. The erasure is commenced by clicking the 

Destroy

” 

button on the screen which activates the charging of the powerful degaussing magnetic field.

 

 

A window opens on the screen showing the progress of the degaussing cycle. When the display shows the degauss 

 

cycle 

is complete the lid can be opened and the media removed. 

The  entire  process  takes  just  45  seconds. 

Throughout the 

whole erase cycle the on

-

board processor monitors the erase procedure ensuring that it is completed correctly. The operator 

is immediately alerted to any interruptions in the cycle by messages on the screen.

 

 

The  lower  portion  of  the  screen  now  shows  all  the  details  of  the  erasure  including  Date,  Time,  Media  Serial  Number, 

Capacitor  Voltage,  Magnetic  Gauss  Field  and  confirmation  that  the  media  was  degaussed  successfully.  If  this  data  is 

highlighted  and  the  print  button  pressed  all  the  details  on  the  screen  along  with  all  the  data  entered  will  be  printed  as  a 

report. As new media is erased the details will be added to the Media Processed Log in the lower half of the screen.

 

 

By  highlighting  erase  records,  the  logs  of  one  or  more  can  be  printed  as  required.  There  is  a  Supervisor  Section  in  the 

Software which is Password protected. This allows the Supervisor to decide which fields are required and which fields must 

be completed by the Operator. The log record is stored on the PC and can be archived at any time or exported as a .csv file.

 

 

After degaussing, hard drives should not be reused as they are stressed in the erasure process and parts can be damaged. 

Backup tapes cannot be used after erasure as the control track may be erased in the degaussing process.

 

 

To use the degausser without the Data Logging Software disconnect the USB Cable and reboot the degausser.

 

Содержание DATAGAUSS LG ZZ201207

Страница 1: ...ZZ201207 ZZ201208 ZZ201209 ZZ201211 ZZ201212 ZZ201213 Rev 12...

Страница 2: ...hey remove any wrist watches prior to using the unit and that any credit cards or other magnetic devices are placed out of range CAUTION it is recommended that magnetic storage media is kept at least...

Страница 3: ...ar purpose and non infringement SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU YOU MAY ALSO HAVE OTHER LEGAL RIGHTS WHICH VARY FROM JUR...

Страница 4: ...atagauss LG XL LG Degaussers 6 5 Software Installation 6 6 Operation Guide 9 7 Erasure Logger Software 11 8 Interrogating the Database 16 9 Printing Records 17 10 Supervisor Screen 19 11 Safety Recomm...

Страница 5: ...E 5 C 41 F to 40 C 104 F HUMIDITY 10 to 80 non condensing MOUNTING Free standing table top DIMENSIONS DataGauss LG 13 9 x 9 2 x 14 3 35cm x 23cm x 36cm DataGauss XL LG 13 9 x 9 7 x 14 3 35cm x 24 6cm...

Страница 6: ...e it from the packing box 3 2 Power Wiring Power connection is made to the Datagauss degausser in the form of an IEC type electrical lead supplied The user should ensure that their power supply meets...

Страница 7: ...201211 ZZ201212 ZZ201213 Page 7 of 30 Close all Windows programs that are running and click NEXT Tick the box to confirm you have read and accept the software licence conditions and click NEXT Check t...

Страница 8: ...ts LTD ZZ201207 ZZ201208 ZZ201209 ZZ201211 ZZ201212 ZZ201213 Page 8 of 30 Select the number of Users and click NEXT Click NEXT to start the installation Click FINISH to complete the installation of th...

Страница 9: ...moved The entire process takes just 45 seconds Throughout the whole cycle the onboard processor monitors the erase procedure ensuring that it is completed correctly The operator is immediately alerted...

Страница 10: ...up the data entry if required When the logging program has been opened on the PC and the DataGauss is connected the operator simply clicks on the Find Machine button for all the unit details to be au...

Страница 11: ...edia destruction is completed It is possible to interrogate the database to retrieve the destruction information record This record or a number of records can be printed out using any printer attached...

Страница 12: ...nternet or is running Windows XP then it will be necessary to install the USB drivers manually If you received a CDROM installation disc from VSSP the FDTI USB drivers and installation instructions ar...

Страница 13: ...Owner panel can be used to clear all the entries in the panel if required 7 3 1 Bar Code Scanner If the bar code scanner has been installed it can be used to enter bar code data such as serial number...

Страница 14: ...elevant data boxes have entries destruction will commence and the following screen is displayed When the destruction process has completed the destruction data is shown in the Media Processed box The...

Страница 15: ...abel print job to the Windows Print Spooler the Windows Print Spooler is responsible for sending the print Data to the selected printer If the selected printer is switched off or disconnected there is...

Страница 16: ...The above can be repeated for each record that is to be viewed 8 2 Resuming Destruction after Interrogation When the database records are being interrogated the DESTROY button is disabled To enable th...

Страница 17: ...nter Page 1 20 06 2014 14 31 28 Media Destruction Record Company Name VSSP Operator Victoria Supervisor Brian Degaussing on Site Yes Media Owner Company Name ICL Engineering Department Engineering Med...

Страница 18: ...he Control Ctrl key down and click the individual records to be printed When you have selected the records to be printed click the Print button the normal print dialog box will be displayed Select the...

Страница 19: ...be displayed To enter the Supervisor screen the correct password must be entered The default password is password Note that this is all lower case The password can be changed in the supervisor screen...

Страница 20: ...e Logger main Screen This allows the supervisor to specify exactly which Data Entry Boxes are to be displayed on the Logger main screen On the Mandatory sub panel a tick box with a tick in it will cau...

Страница 21: ...Password button 10 4 Printer Line Spacing The Printer Line Spacing setting allows the lines on the printed records to be adjusted If the lines on the printer are too close together increase the value...

Страница 22: ...lect Printer Button This will cause the Windows Print Setup box to be displayed Select the required printer from the list and click OK NOTE The label print application is designed to work with a Broth...

Страница 23: ...he print job will sit in the Windows Print Spooler Queue until the selected printer becomes available At this point the print job is printed as are any other queued print jobs Logo Offset The logo off...

Страница 24: ...rd Windows Save File dialog box The supervisor can then choose a location e g drive and or folder to store the archive file The supervisor can also name the file as required The file name can be defin...

Страница 25: ...ia Info Capacity 18 Media Info PN 19 Media Info Class 20 Media Info Remarks 21 Capacitor Voltage Volts 22 Magnetic Field Strength Gauss 23 Result Degaussed Crushed Failed etc Field number 01 is the fi...

Страница 26: ...cluding the label printer name and the database file name NOTE Do not change the contents of the ini file the logger application may become unusable 10 6 4 Moving the Database The storage location and...

Страница 27: ...on This displays the windows save as dialog navigate to the directory you wish to save the database file in Enter the required name for the database and click save The below dialog box shows the name...

Страница 28: ...Linux based server on the network it uses the SMB File sharing protocols to allow Windows Sharing The below database screen shows that the database has been created in the network location QNAP 1 Tes...

Страница 29: ...re placed out of range SECTION 12 MAINTENANCE 12 1 Resetting the circuit breaker The DataGauss Degasser is not equipped with any on board fuses that require replacement All the systems within the unit...

Страница 30: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA...

Отзывы: