4

 

OC32/NG 

 

4.1

 

Introduction 

 

 

Fig 15: OC32/NG (2 modules shown) 

 

The OC32 can be used to control all accessories on and around your railroad and many other 
applications. This manual applies to the use of the OC32/NG version only. If you have the 
previous version of the OC32 (not /NG), please refer to previous versions of this Dinamo P&P 
manual. 
 
The possibilities of the OC32 are almost infinite. It is impossible to cover all topics in this 
Dinamo P&P manual. We therefore limit the description here to how you power the OC32/NG 
and how you can connect the OC32/NG to the Dinamo Network. 
 
In most cases the OC32 has to be configured before it can be used to control devices in 
your miniature world. This configuration is done by the OC32Config program. For a 
description how to connect devices to your OC32 and how to configure the OC32, please 
consult the appropriate OC32 manuals. 
 

Control your miniature world 

 

Manual DINAMO Plug & Play 

 

2017 Leon van Perlo  

Version 1.2 – Dec 21

st

, 2017 

Page 17 of 32 

4.2

 

Overview of the OC32/NG and location of connections and functions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig 16: OC32/NG Overview 

 
The above picture only shows the elements relevant for this manual. For a complete 
overview, please consult the OC32/NG and OC32 configuration manuals. 
 

4.3

 

Mounting the OC32/NG 

 
As the TM44, the OC32/NG is intended to be placed behind or underneath your miniature 
world. The OC32/NG is very flexible and configurable. Note that the OC32/NG can be used 
simultaneously for many other things beside your train-accessories. Use the flexibility to 
place your OC32/NG’s at strategic locations throughout your miniature world and keep the 
wiring to your devices short and tidy. 
 
The OC32/NG (bare unit) has 4 mounting holes (3mm). Preferably use spacers 
(approximately 10 mm)  when mounting the OC32/NG, so that the back of the module does 
not get into contact with the mounting panel. This is especially important when you mount 
the OC32/NG on a metal surface! When mounting the OC32/NG on a metal surface, keep 
especially in mind that the mounting holes are connected to 0V/GND and that the metal 
mounting surface will carry the same potential in this case.  
 
The OC32/NG’s (as bare unit) are ”stackable” by using M3 x 20mm spacers between the 
modules. You can even stack TM44’s and OC32/NG’s since the mounting holes are aligned. 
When mounting the modules, make sure to allow for enough space to insert the connectors 
including cables and make sure you can still access the dipswitches at the side.  
 

LED Green

LED Orange

RS485

interface

Power

Serial Address
Selection

RS485 Termination

Mounting hole

Mounting
hole

Mounting hole

Mounting
hole

LED Green

LED Orange

RS485

interface

Power

Serial Address
Selection

RS485 Termination

Mounting hole

Mounting
hole

Mounting hole

Mounting
hole

Содержание Dinamo

Страница 1: ...st 2017 2017 Leon van Perlo This page is intentionally left blank Author Leon J A van Perlo Version 1 2 Date December 21 st 2017 DINAMO Plug Play Manual VPEBVan Perlo Elektronica Besturingstechniek VP...

Страница 2: ...pt as in this manual starting from 0 0 TM44 0 1 2 3 0B0 0B1 0B2 0B3 1B0 1B1 1B2 1B3 2B0 2B1 2B2 2B3 3B0 3B1 3B2 3B3 0 0 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 1 5 6 7 8 65 66 67 68 69 70 71...

Страница 3: ...ctivated Fig 35 Connecting turnout tracks by relays Relays for this application can be obtained from a regular electronics components store Types that are specified to switch 1Amp per contact are fine...

Страница 4: ...on the requirements of the software so for details you should consult the manual of your control software Dinamo P P provides 4 sections per block It is not necessary to use all of them In most cases...

Страница 5: ...a lot easier than changing your physical layout block 2 block 3 block 1 block 4 T1 T2 block 2 block 3 block 1 block 4 T1 T2 block 2 block 1 T3 T2 T1 block 3 block 4 block 5 block 2 block 1 T3 T2 T1 b...

Страница 6: ...start with If you want to become more familiar with the TM44 and RM C settings consult the respective manuals or have a look at the firmware release notes at https www dinamousers net 6 4 Configuring...

Страница 7: ...Handle TM44 modules to control trains Handle OC32 NG modules to control accessories being everything except the trains themselves 2 2 Communication power supply and mounting The RM C communicates with...

Страница 8: ...nd assigned unique addresses to all modules you can verify whether they are correctly identified by your RM C While the power to your Dinamo system is off and your RM C is connected to your PC watch t...

Страница 9: ...This indicates your PC and RM C can communicate If System Version shows an older version than 1 30A update the firmware of your RM C otherwise a large part of this manual does not apply to your system...

Страница 10: ...0 0 to 15 7 for blocks and similar for sections Some control programs even give you a choice between different numbering schemes Also pay attention that many programs start numbering at 1 and therefo...

Страница 11: ...Off On On 3 1 Off Off Off On On 4 0 On On On Off On 4 1 Off On On Off On 5 0 On Off On Off On 5 1 Off Off On Off On 6 0 On On Off Off On 6 1 Off On Off Off On 7 0 On Off Off Off On 7 1 Off Off Off Of...

Страница 12: ...shall be powered by a DC power only Power supply is delivered to the TM44 through connector K1 This connector has 4 term inals from which P P only uses Pin 1 and 2 So do not connect pin 3 and 4 see fi...

Страница 13: ...s to a large extent on the properties of the trains whether they have illumination etc The internal consumption of the TM44 can be ignored in the calculations For the running power voltage so what you...

Страница 14: ...le it is highly recommended to keep the wires of a single Block together Therefore a multi conductor cable per block is the preferred option If lengths are limited to approx 4 meters you can use UTP L...

Страница 15: ...e OC32 is connected to pin 1 and 2 on the 4 pole connector See fig 17 Fig 17 Connecting power supply to the OC32 PWR GND DO NOT CONNECT PWR GND DO NOT CONNECT Control your miniature world Manual DINAM...

Страница 16: ...figuration manuals 4 3 Mounting the OC32 NG As the TM44 the OC32 NG is intended to be placed behind or underneath your miniature world The OC32 NG is very flexible and configurable Note that the OC32...