FITTING
DESC.
EQUIVALENT
FEET
OF PIPE
FITTING DESC.
EQUIVALENT
FEET
OF PIPE
FITTING DESC.
EQUIVALENT
FEET OF
PIPE
3” 90
5’
2” 90
5’
4” 90
3’
3” 45
3’
2” 45
3’
4” 45
1’
3” Coupling
0’
2” Coupling
0’
4” Coupling
0’
3” Tee
0’
2” Tee
0’
4” Pipe
1’ = 1’
3” Pipe
1’ = 1’
2” Pipe
1’ = 1’
4” Tee
0’
3” Concentric vent kit
3’
2” Concentric vent kit
3’
3” V1000 vent kit
0’
VENTING EXAMPLES (NOTE:
SHOWN AS INTAKE & EXHAUST PIPE AND FITTINGS ADDED TOGETHER)
* = MINIMUM VENT LENGTH
** = MAXIMUM VENT LENGTH
TOTAL
COMBINED
VENT LENGTH
(FEET)
INTAKE &
EXHAUST
QTY.
OF 90
°
ELBOWS
EQUIVALENT
FRICTION
LOSS
(FEET)
FOR EACH
ELBOW
TOTAL
FRICTION
LOSS
FOR
ELBOWS
GRAND TOTAL
VENT LENGTH
(FEET)
WITH FITTING
FRICTION
LOSS ADDED
*12
2
5
10
22
20
2
5
10
30
20
3
5
15
35
20
4
5
20
40
20
5
5
25
45
20
6
5
30
50
20
7
5
35
55
20
8
5
40
60
20
9
5
45
65
20
10
5
50
70
20
11
5
55
75
20
12
5
60
80
20**
13
5
65
85**
30
3
5
15
45
30
4
5
20
50
30
5
5
25
55
30
6
5
30
60
30
7
5
35
65
30
8
5
40
70
30
9
5
45
75
30
10
5
50
80
30**
11
5
55
85**
40
3
5
15
55
40
4
5
20
60
40
5
5
25
65
40
6
5
30
70
40
7
5
35
75
40
8
5
40
80
40**
9
5
45
85**
50
3
5
15
65
50
4
5
20
70
50
5
5
25
75
50
6
5
30
80
50**
7
5
35
85**
60
3
5
15
75
60
4
5
20
80
60**
5
5
25
85
70**
3
5
15
85
FRICTION LOSS EQUIVALENCE TABLES
2" VENTED MODELS
AFTER THE FIRST 10’ OF 3"
3" VENTED MODELS
SSV100-45R/SSV130-45R
ONLY4" EQUIVALENT TABLE
Содержание SSV130-119R
Страница 12: ...PAGE 12...
Страница 15: ...PAGE 15...
Страница 16: ...PAGE 16...
Страница 17: ...PAGE 17...
Страница 18: ...PAGE 18...
Страница 19: ...PAGE 19...
Страница 22: ...PAGE 22...
Страница 23: ...PAGE 23...
Страница 24: ...PAGE 24...
Страница 25: ...PAGE 25...
Страница 29: ...PAGE 29 PARTS ILLUSTRATIONS...
Страница 39: ...PAGE 39...
Страница 40: ...PAGE 40 2008 2006 2005 2004 Heat Transfer Products Inc...