REPLACEMENT PARTS NOT SHOWN
LOW VOLTAGE CABLE ASSEMBLY
(710B0041)
INTERCONNECT RIBBON CABLE
(7000-665)
LINE CABLE
(710B0048)
PUSH BUTTON
(7000-667)
TRANSFORMER
(7000-666)
GASKET BURNER MOUNTING FLANGE
(G5010)
GASKET BLOWER OUTLET FLANGE
(G5020)
GASKET AIR INLET
(G5030)
GASKET BURNER MOUNTING FLANGE WHITE
(7000-815)
ORIFICES
All of the Voyager gas fired water heaters have unique air and gas orifice sizes. Special attention should be paid to these sizes when-
ever converting a heater from one fuel type to another, or when the orifice is changed for any reason. Below is a list of orifice sizes for
conversions to other fuel types and the sizes the voyager was shipped with from the factory. Please note that air orifices do not have
to be changed when switching from one fuel type to another. This information is not intended to allow field conversions by drilling ori-
fices. This is only a guide to correct orifice sizing.
All orifices must be obtained through the factory with all necessary labels and the serial number must be provided to the factory
OR
WARRANTY WILL BE VOIDED
.
VOYAGER GAS CONVERSION INSTRUCTIONS
FOR CONVERSION OF THE VOYAGER TO PROPANE OR NATURAL GAS. YOU MUST ORDER A CONVERSION KIT FROM THE
FACTORY. BELOW IS A LIST OF THE DIFFERENT MODEL NUMBERS YOU WILL NEED TO REFERENCE WHEN ORDERING
YOUR KIT. PLEASE CALL THE FACTORY AT 1-800-323-9651, CUSTOMER SERVICE TO PLACE YOUR ORDER.
100,000 PROPANE TO NATURAL – (N10AG)
100,000 NATURAL TO PROPANE – (P10AG)
130,000 PROPANE TO NATURAL – (N13AG)
130,000 NATURAL TO PROPANE – (P13AG)
160,000 PROPANE TO NATURAL – (N16AG)
160,000 NATURAL TO PROPANE – (P16AG)
199,000 PROPANE TO NATURAL – (N19AG)
199,000 BTU VOYAGERS-
GAS ORIFICE SIZES-
AIR ORIFICE = 1.375"
NATURAL GAS = .379"
PROPANE/LP GAS =
.295"
160,000 BTU VOYAGERS-
GAS ORIFICE SIZES-
AIR ORIFICE = 1.375"
NATURAL GAS = .362"
PROPANE/LP GAS =
.295"
130,000 BTU VOYAGERS-
GAS ORIFICE SIZES-
AIR ORIFICE = 1.125"
NATURAL GAS = .280"
PROPANE/LP GAS =
.235"
NATURAL GAS CONVERSION FROM PROPANE/LP =
.285"
PROPANE/LP GAS CONVERSION FROM NATURAL GAS = .250"
CAUTION:
THERE ARE NO USER SERVICEABLE PARTS WITHIN THE CONTROL SYSTEM. TO MAINTAIN SAFETY AND PROPER APPLI-
ANCE PERFORMANCE, REFER ALL TROUBLE-SHOOTING TO QUALIFIED SERVICE PERSONNEL.
n
WARNING
You must not drill orifices. The result will be poor ignition, explosion, severe bodily injury or death.
Содержание SSV130-119R
Страница 12: ...PAGE 12...
Страница 15: ...PAGE 15...
Страница 16: ...PAGE 16...
Страница 17: ...PAGE 17...
Страница 18: ...PAGE 18...
Страница 19: ...PAGE 19...
Страница 22: ...PAGE 22...
Страница 23: ...PAGE 23...
Страница 24: ...PAGE 24...
Страница 25: ...PAGE 25...
Страница 29: ...PAGE 29 PARTS ILLUSTRATIONS...
Страница 39: ...PAGE 39...
Страница 40: ...PAGE 40 2008 2006 2005 2004 Heat Transfer Products Inc...