background image

  

- 4 - 

  

 

Safety Regulations and Appropriate Application: 

The tank measuring sensor has been designed according to the valid safety regulations. 
Application is only allowed, if the unit is in technically faultless condition, with protected board battery 

voltage of the indicated value and only for measurement of water or hydrous media. 

 

Never use the unit at locations where the risk of gas or dust explosion exists! 

 

The unit is to be disconnected from any connection prior to execution of electrically welding or work on 

the electric system. 

 

Cables are always to be laid in such a way that damage is excluded. Observe to fasten them tightly.

 

 

Never lay 12 V (24 V) cables and 230 V mains supply cables into the same cable conduit (empty conduit).

 

 

Check live cables or leads periodically for insulation faults, points of break or loosened connections. 

Occurring defects must be remedied immediately. 

 

If the user is not able to draw from the manual, which characteristic values are valid for a unit or which 

regulations are to be observed, a specialist is to be consulted. 

 

The user/buyer is obliged to observe any construction and safety regulations. 

 

The unit is not equipped with parts, which can be replaced by the user.  

 

The warranty period is 24 months from the purchase date (against presentation of the sales slip or 

invoice). 

 

The warranty will be void in case of any inappropriate utilisation of the unit, if it is used beyond the 

technical specification, in case of improper operation or external intervention. We do not assume any 

liability for any damage resulting hereof. The liability exclusion is extended to any service being executed 

by third, which has not been ordered by us in writing. Service is to be effected exclusively by VOTRONIC  

D-36341 Lauterbach. 

 
 

 

Declaration of Conformity: 

According to the stipulations of the regulations 2006/95/EG, 2004/108/EG, 95/54/EG this product 

corresponds to the following standards or standardized documents:   

EN55014;  EN55022 B;  DIN14685;  DIN40839-1;  EN61000-4-2;  EN61000-4-3;  EN 61000-4-4.

 

 

 

Disposal of 

the product 

in the  

household waste 

is not 

allowed.

 

The product 

conforms to RoHS.  

Thus, it complies 

with the directives for Reduction of 

Hazardous  Substances in Electrical and 
Electronic Equipment

 

 

Technical Data:  

Operating Voltage:

 

12 V-/24 V-DC Battery voltage (of the display) 

Operating Voltage Range:

 

7...32 V 

Current Consumption:

 

4...7 mA 

Signal Output 0...100 %:

 

0...2.2 V, 

Measuring Method:

 

capacitive, suitable for short-time and continuous operation 

Tank Height, adjustable:

 

12…24 cm, 15…50 cm 

Mounting Hole:

 

38 mm or thread PG 29 

Flange Diameter: 

 

46.5 mm 

Length Connection Cable:  

75 cm 

 

 

 

 

 

 

 

 

Subject to misprints, errors and technical modification without notice. 
All rights reserved, particularly the right of reproduction. Copyright 

 VOTRONIC 12/14. 

Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, 36341 Lauterbach/GERMANY 

Phone: +49 (0)6641/91173-0     Fax: +49 (0)6641 / 91173-20    E-mail[email protected]     Internet: www.votronic.de   

Delivery Scope:  

 

Tank Electrode 12-24 K or 15-50 K 

 

Coupling Ring PG 29 

 

Packing Washer 

 

Mounting Instructions

 

Содержание 5543

Страница 1: ...87 All Types All Types For remote level measurement the tank electrode is installed directly at the tank It is suitable for Fresh water if applicable please observe the Guidelines for Drinking Water Quality DIN 2001 2 Sewage water grey water Feces sewage water Plastic tanks any material Metal tanks aluminium steel stainless steel etc Adjustable to tank heights 12 to 24 cm or 15 cm to 50 cm Functio...

Страница 2: ...nk electrode 12 24 K is for best results if possible the installation outside recommended Installation inside Installation outside After that the two stick probes must be cut to identical length metal saw strong side cutter bolt cutter It is important that a clearance of at least 10 20 mm is left between tank bottom and probe ends deposit up and down movement of the tank bottom and of the tank top...

Страница 3: ... the tank electrode out of the full tank or bucket Fine adjustment of the set water depth can be corrected or changed at any time with full tank Final Installation The delivered packing washer is placed between tank and casing flange Screw the tank transmitter in place using the coupling ring In case of underfloor installation of the tank the adjuster must be protected with a permanently elastic s...

Страница 4: ...ication in case of improper operation or external intervention We do not assume any liability for any damage resulting hereof The liability exclusion is extended to any service being executed by third which has not been ordered by us in writing Service is to be effected exclusively by VOTRONIC D 36341 Lauterbach Declaration of Conformity According to the stipulations of the regulations 2006 95 EG ...

Отзывы: