Preliminary Installation:
The tank electrode is designed for vertical installation from the tank top.
In contrast to sewage water and feces tanks (deposit), an installation at the lower side of the tank is also possible.
The tank electrode should be placed at the topmost location and in the tank centre.
Mounting hole, diameter 38 mm, or thread PG29.
Depending on the local conditions (available space above the tank, cutout of the intermediate floor, tank height etc.), the
tank transmitter can be installed at the tank inside or outside (for the short type tank electrode 12-24 K is for best results, if
possible, the installation outside recommended):
Installation inside
Installation outside
After that, the two stick probes must be cut to identical length (metal saw, strong side cutter, bolt cutter).
It is important, that a clearance of at least 10 - 20 mm is left between tank bottom and probe ends (deposit, up-and-down
movement of the tank bottom and of the tank top during driving etc.)
Burr the sticks, and reinsert the insulating cap on the stick probe being insulated by the plastic pipe.
A thorough sealing between the insulating cap and the plastic pipe is decisive for proper operation of the tank electrode!
Set the adjuster tank height "FULL" 100 %:
Example:
The scale
indicates
the value 18 cm
as adjusted
Tank Height