XR3D-6 Maintenance & Troubleshooting
EM-XR3D-6-001-EN.D
5-3
©2011 VOTI Inc.
AC/DC POWER TROUBLESHOOTING CHART
PROBLEM
CAUSE
CORRECTIVE ACTION
One the digital outputs does not work.
Check cable connections of the Control
Box, the Motor drive in the base and/or
the Computer on the top.
There is no object but EC1 and/or EC2
appear red.
Photo sensors misaligned, realign them.
There is an object but EC1 and/or EC2
appear green.
Photo sensors are defective, check
connections.
“Interlock” appears green even when
switches are pulled off (or when doors
are closed).
One of the access panel switches is not
connected or defective. Check
connections.
“Keylock” appears green even when
turned on.
Operator “Keylock” switch is not
connected or defective, check the
connection.
X-Ray source and conveyor motor do
not start when Operator key switch
toggled.
Interlock switch not making contact
–
Interlock Message appears on Operator
screen.
Check the Access Panels to ensure they
are correctly seated on their locking
slots. See
Interlock Message on the Operator
screen.
Operator not standing on Safety mat or
mat.
Stand on the mat to see if the Interlock
message on the Operator screen goes
away.
Check the connector and if faulty
replace the mat. See
Access panel Interlock switches are not
depressed.
Check that the Interlock switches in the
Access Panels are closed to complete
the 12VDC circuit. See
5.2.1 Check Keypad Faults
Fault
Problem
Possible Cause
Corrective Action
F01
Control Box cannot
communicate with
BioSans
BioSans was improperly closed.
The USB Communication cable is not plugged
in.
BioSans does not work correctly.
Control Box does not work correctly.
Reset BioSans by turning on and off the
computer.
Ensure the USB cable is securely
connected to the Keypad Control Box.
Reset the system.
Contact VOTI technical support.
F02
Emergency Stop
activated
Emergency button has been pressed.
There is an internal fault.
Release the Emergency button.
Contact VOTI technical support.
F03
Interlock activated
Access Panel has been intentionally opened.
There is an internal fault.
Close the Access Panel.
Contact VOTI technical support.
Содержание XR3D-6
Страница 2: ...XR3D 6 Maintenance Troubleshooting ii EM XR3D 6 001 EN D 2011 VOTI Inc...
Страница 5: ...XR3D 6 Maintenance Troubleshooting EM XR3D 6 001 EN D v 2011 VOTI Inc 7 XR3D 6 Safety Features 7 1...
Страница 6: ......
Страница 20: ...XR3D 6 Maintenance Troubleshooting 2 8 EM XR3D 6 001 EN D 2011 VOTI Inc...
Страница 32: ...XR3D 6 Maintenance Troubleshooting 3 12 EM XR3D 6 001 EN D 2011 VOTI Inc...
Страница 48: ...XR3D 6 Maintenance Troubleshooting 3 28 EM XR3D 6 001 EN D 2011 VOTI Inc...
Страница 52: ...XR3D 6 Maintenance Troubleshooting 4 4 EM XR3D 6 001 EN D 2011 VOTI Inc...