20 Startup failure
H1
Outdoor
21 Compressor phase current peak protection
H2
Outdoor
22 Compressor phase current RMS protection
H3
Outdoor
23 IPM protection
H4
Outdoor
24 IPM overheat protection
H5
Outdoor
25 Compressor phase circuit detection error
H6
Outdoor
26 Phase loss
H7
Outdoor
27 Outdoor DC fan motor error
H8
Outdoor
28
Outdoor DC fan phase current detection circuit
error
H9
Outdoor
29 Jumper error
L0
Indoor
30 Zero detection circuit error
L1
Indoor
31 Indoor fan motor error
L2
Indoor
32
Indoor display communication error between
the indoor unit and outdoor unit
L3
Indoor
33 Select the port level abnormal error
L4
Indoor
34 Indoor EEPROM error
L5
Indoor
35
Outdoor display communication error between
the indoor unit and outdoor unit
L6
Outdoor
37 Outdoor unit EEPROM error
P0
Outdoor
38 Charging circuit error
P1
Outdoor
39 Feedforward voltage protection
P2
Outdoor
40 Over voltage protection
P3
Outdoor
41 Low voltage protection
P4
Outdoor
42 DC link voltage drop error
P5
Outdoor