0
1
Vortex
®
- VX 2400LP Series
The VX 2400LP series are SURFACE mount mounting. The VX 2400LP
model uses a miniature LED and a large strip LED for long distance door
monitoring and smarter look (see LED feature p3).
The VX 2400LP series needs DC and stabilised power. The voltage
(measured at the lock) must be correct for the magnet to retain the
armature plate with its highest holding force capacity. When an external
pressure is applied, the combined technology of magnetic force and
swivel pin held inside the magnet hole by six metal marbles will ensure a
holding force of > 15 000 N (~ 1 500 kgf). Cutting the power to the lock will
remove the magnetic force and the marbles release themselves from pin
head to unlock the door. The Vortex
®
VX 2400LP works in 12 or 24VDC. A
reed contact is integrated for a complete locking monitoring. This
monitoring only works if the armature plate is fitted flexibly and if the
power supply is correct at the lock input. Another reed contact provides
the door status. The exit button (or keypad, prox reader…) must be wired
on 12VDC (or 24VDC), not on the input wiring of power supply.
Also, this Vortex lock is equipped with a contact with 1 output able to
detect any pressure on the locked door. This contact could be connected
to an alarm system or local alarm to warn BEFORE the access is opened
without authorisation. A built-in buzzer will sound simultaneously.
The PSU output must not be connected to the earth but isolated to avoid
any kind of electric sparks, therefore damaging the lock and its surfaces.
Wiring and Power Input
To prevent irreversible damage to the unit, ensure that wiring is connected
correctly before supplying power to the mechanical electro magnet
.
NO - DSS (BLUE)
NO (PURPLE)
COM (ORANGE)
NC (PINK)
NO-LSS (YELLOW)
- (BLACK)
NO - DSS (BLUE)
NO-LSS (YELLOW)
12/24 VDC
12VDC/0.36A, 24VDC/0.18A
30 VDC max
0.3 A max, 10 W max
EW, 50VDC,
0.3A max
30 VDC max
0.3 A max, 10 W max
Buzzer Enabled
- Close
+(RED)
(BROWN)
(WHITE)
Buzzer Disabled - Open