Chapter 1 Introduction
M-000-00010
1-9
Line Size / Process Connections / Materials
The M22/M24 In-line model is built for line sizes ½ through 4 inch wa-
fer or ½ through 12 inch flanged design using ANSI 150, 300, 600,
PN16, 40, or 64 class flanges. JIS flanges available upon request.
The M23 Insertion model can be used in line sizes 2 inch and greater and
is built with a compression fitting or packing gland design using 2 inch
NPT, or 2 inch flanged connections (ANSI 150, 300, 600, PN16, 40, or
64 class flanges). The packing gland design can be ordered with a per-
manent or removable retractor.
The M22/M24 In-line model can be built with A105 carbon steel, 316L
stainless steel, or Hastelloy C-276. The M23 Insertion model can be
built with 316L stainless steel or Hastelloy C-276.
Flow Meter Electronics
Pro-V Flow Meter electronics are available mounted directly to the flow
body, or remotely mounted. The electronics housing may be used indoors
or outdoors, including wet environments. Available input power options
are: DC loop powered (2-wire), DC powered, or AC powered. Three an-
alog output signals are available for your choice of three of the five pro-
cess variables: mass flow rate, volumetric flow rate, temperature, pres-
sure or fluid density. A pulse output signal for remote totalization and
MODBUS, HART, and BACnet communications are also available.
Pro-V Flow Meters include a local 2 x 16 character LCD display housed
within the enclosure. Local operation and reconfiguration is accom-
plished using six pushbuttons operated via finger touch. For hazardous
locations, the six buttons can be operated with the electronics enclosure
sealed using a hand-held magnet, thereby not compromising the integrity
of the hazardous location certification.
The electronics include nonvolatile memory that stores all configuration
information. The nonvolatile memory allows the flow meter to function
immediately upon power up, or after an interruption in power.
All
flowmeters are calibrated and configured for the customer
’
s flow
application.
Содержание Pro-T
Страница 10: ...Table of Contents Series M22 M23 M24 Instruction Manual 0 10 M 000 00010...
Страница 20: ...Chapter 1 Introduction Series M22 M23 M24 Instruction Manual 1 10 M 000 00010...
Страница 60: ...Chapter 2 Installation Series M22 M23 M24 Instruction Manual 2 40 M 000 00010...
Страница 126: ...Chapter 5 Troubleshooting Repair Series M22 M23 M24 Instruction Manual 5 16 M 000 00010...
Страница 140: ...Appendix B Approvals Series M22 M23 M24 Instruction Manual B 4 M 000 00010...
Страница 150: ...Appendix D Glossary Series M22 M23 M24 Instruction Manual D 4 M 000 00010...