![VorTek Pro-T Скачать руководство пользователя страница 127](http://html1.mh-extra.com/html/vortek/pro-t/pro-t_instruction-manual_1050443127.webp)
Series M22/M23/M24 Instruction Manual
Appendix A Specifications
M-000-00010
A-1
Appendix A Product Specifications
Accuracy
Process
Variables
M22/M24 Series In-Line Meters
M23 Series Insertion Meters
(1)
Liquids
Gas & Steam
Liquids
Gas & Steam
Mass Flow
Rate
±1% of rate
over a 30:1
range
(3)
±1.5% of rate
(2)
over a 30:1
range
(3)
±1.5% of
rate over a
30:1
range
(3)
±2% of rate
(2)
over a 30:1
range
(3)
Volumetric
Flow Rate
±0.7% of
rate over a
30:1
range
(3)
±1% of rate over
a 30:1 range
(3)
±1.2% of
rate over a
30:1
range
(3)
±1.5% of rate
over a 30:1
range
(3)
Temperature
± 2° F
(± 1° C)
± 2° F
(± 1° C)
± 2° F
(± 1° C)
± 2° F
(± 1° C)
Pressure
0.3% of
transducer
full scale
0.3% of
transducer full
scale
0.3% of
transducer
full scale
0.3% of
transducer full
scale
Density
0.3% of
reading
0.5% of
reading
(2)
0.3% of
reading
0.5% of
reading
(2)
Notes:
(1) Accuracies stated are for the total mass flow through the pipe.
(2) Over 50 to 100% of the pressure transducer’s full scale.
(3) Nominal rangeability is stated. Precise rangeability depends on fluid and pipe size.
Repeatability
Mass Flow Rate: 0.2% of rate.
Volumetric Flow Rate: 0.1% of rate.
Temperature: ± 0.2° F (± 0.1° C).
Pressure: 0.05% of full scale.
Density: 0.1% of reading.
Stability Over 12 Months
Mass Flow Rate: 0.2% of rate maximum.
Volumetric Flow Rate: Negligible error.
Temperature: ± 0.1° F (± 0.5° C) maximum.
Pressure: 0.1% of full scale maximum.
Density: 0.1% of reading maximum.
Response Time
Adjustable from 1 to 100 seconds.
Material Capability
Series M22/M24 In-Line Flow Meter:
Any gas, liquid or steam compatible with 316L stainless steel, C276
hastelloy or A105 carbon steel. Not recommended for multi-phase flu-
ids.
Series M23 Insertion Flow Meter:
Any gas, liquid or steam compatible with 316L stainless steel. Not
recommended for multi-phase fluids.
Flow Rates
Typical mass flow ranges are given in the following table. Precise
flow depends on the fluid and pipe size. M23 insertion meters are
applicable to pipe sizes from 2 inch and above. Consult factory for
sizing program.
Water Minimum and Maximum Flow Rates
½-inch
¾-inch
1-inch
1.5-inch
2-inch
3-inch
4-inch
6-inch
8-inch
15 mm
20 mm
25 mm
40 mm
50 mm
80 mm
100 mm
150 mm
200 mm
gpm
1
22
1.3
40
2.2
67
5.5
166
9.2
276
21
618
36
1076
81
2437
142
4270
m
3
/hr
.23
5
.3
9.1
0.5
15
1.3
38
2.1
63
4.7
140
8.1
244
18
554
32
970
Содержание Pro-T
Страница 10: ...Table of Contents Series M22 M23 M24 Instruction Manual 0 10 M 000 00010...
Страница 20: ...Chapter 1 Introduction Series M22 M23 M24 Instruction Manual 1 10 M 000 00010...
Страница 60: ...Chapter 2 Installation Series M22 M23 M24 Instruction Manual 2 40 M 000 00010...
Страница 126: ...Chapter 5 Troubleshooting Repair Series M22 M23 M24 Instruction Manual 5 16 M 000 00010...
Страница 140: ...Appendix B Approvals Series M22 M23 M24 Instruction Manual B 4 M 000 00010...
Страница 150: ...Appendix D Glossary Series M22 M23 M24 Instruction Manual D 4 M 000 00010...