![VorTek Pro-T Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/vortek/pro-t/pro-t_instruction-manual_1050443142.webp)
Appendix C Flow Meter Calculations
Series M22/M23/M24 Instruction Manual
C-2
M-000-00010
Insertion Flow Meter Calculations
Flowing Velocity
Volume Flow Rate
Mass Flow Rate
Where:
A = Cross sectional area of the pipe (ft^2)
f = Vortex shedding frequency (pulses / sec)
K
c
= Meter factor corrected for Reynolds Number (pulses / ft)
Q
v
= Volume flow rate (ft^3 / sec)
Q
M
= Mass flow rate (lbm / sec)
V
f
= Flowing velocity (ft / sec)
= Density (lbm / ft^3)
c
f
K
f
V
=
A
V
Q
f
V
=
A
V
Q
f
M
=