background image

5

English

-  Before plugging power cord into electrical outlet, be sure that 

all electrical information on the rating label, including voltage, is 
compatible with your outlet’s power supply. 

-  Never use the cord as a handle or otherwise yank, strain or stretch 

the power cord. 

-  While the product is plugged in, do not insert or allow foreign 

objects to enter any input or output opening as this may cause risk 

of electric shock or fire, or damage the product.

-  A loose fit between wall outlet (receptacle) and plug may cause 

overheating and distortion of the plug. Discontinue use of the 

product in this outlet. Contact a qualified electrician to replace 

loose or worn outlets.

-  This appliance has a polarized plug (one blade is wider than the 

other.) To reduce the risk of electrical shock, this plug is intended to 

fit in a polarized outlet only one way. If the plug does not fit fully in 
the outlet, reverse the plug. If it still does not fit, contact a qualified 

electrician. Do not attempt to defeat this safety feature.

-  The product may be hot when in use. To avoid burns, do not let bare 

skin touch hot surfaces. Always allow appliance to cool at least 30 

minutes before moving, refilling or emptying it. Empty all water and 

dry unit before storing.

-  Before filling with water, moving, repositioning, servicing, cleaning 

and when not in use, use the product controls to turn off the 
power and then unplug. To disconnect from outlet, grasp and 
pull only the plug. Also, power off and unplug if the product will 
be left unattended for an extended period of time or during 
electrical storms. 

-  Electric shock can occur when liquid comes in contact with 

electricity. Be careful when removing the water tank and refilling to 

avoid electric shock. Do not pour water through the top Outlet Air 
Grille on the power head.  

-  Turn the humidifier off if the relative humidity exceeds 60%. Humidity 

levels above 60% may allow moisture to build up indoors and 

condense on surfaces, where microorganisms can settle and grow. 

For accurate readings, use a hygrometer which is available at most 

hardware stores and home centers. 

-  The Mist Outlet and Mist Tube must be used when operating 

this product. The Mist Outlet and Mist Tube can be removed for 
cleaning.

SERVICING WARNING—To reduce risk of fire, electrical shock 

and injury to persons, observe the following:

-   Clean your product regularly, only as is instructed in this 

manual. Prior to cleaning, turn off the power on your product 
and unplug.  Do not use gasoline, thinners, solvents, ammonias 
or other chemicals for cleaning. Refer to the CLEANING 
instructions provided.

-   Do not open appliance housing while product is plugged in. To 

avoid risk of shock, all service and/or repairs must be done by a 
Vornado Authorized Service Center. 

-   Protect against the growth of mold, mildew and other 

microorganisms by emptying the water tank immediately after each 
use.  If water is left in the tank for longer than 8 hours, thoroughly 
clean and disinfect the unit as described in the section of this 
Owner’s Guide referenced as “CLEANING”.

DISPOSAL WARNING

To reduce waste and environmental harm, observe the following:

PACKAGE RECYCLING: 

The packaging protects the 

appliance from transport damage. The packaging materials 
are selected from the point of view of their environmental 

Содержание UH100

Страница 1: ...model UH100 ULTRASONIC WHOLE ROOM HUMIDIFIER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS vornado com...

Страница 2: ...2 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right...

Страница 3: ...tant Safety Instructions 4 Getting Started 7 Features 8 Controls 9 Filling Water Tank 10 How To Use 11 Mineral Cartridge 12 Automatic Refill Program 12 Cleaning 13 Storage 16 Troubleshooting 17 Warran...

Страница 4: ...or unstable surface or near water The appliance power supply power cord and plug cannot come into contact with water Do not use this product on wet surfaces Do not use this product in a bathtub or sh...

Страница 5: ...f time or during electrical storms Electric shock can occur when liquid comes in contact with electricity Be careful when removing the water tank and refilling to avoid electric shock Do not pour wate...

Страница 6: ...erence will not occur in a particular installation If this product does cause harmful interference to radio or television reception which can be determined by turning the product off and on the user i...

Страница 7: ...ning of each season the humidifier equipped with a humidistat may run constantly for a day or so and thus evaporate large quantities of moisture When the home and its furnishings have absorbed moistur...

Страница 8: ...ransducer POWER HEAD Powerful motor circulates humidified air throughout whole room MIST TUBE Guides the mist from inside the humidifier to the mist nozzle AIR OUTLET GRILLE Initiates Vornado s signat...

Страница 9: ...to select the fan speed Offers HIGH LOW or AUTO speed selection HUMIDITY Control humidity level at 40 60 or allow unit to run continuously POWER BUTTON Easily operate with power switch that turns the...

Страница 10: ...not twist tank while still in base or Cap may disengage and leak 3 Turn the Water Tank upside down and remove the Cap by turning it counterclockwise B 4 Gently place Water Tank on a flat surface and...

Страница 11: ...turn on the humidity setting may be lower than the room humidity level Increase the humidity set point until the mist and fan turn on This is an indication of the level of humidity already in the roo...

Страница 12: ...Water Tank See FILLING WATER TANK for instructions 2 Unscrew Cap 3 Unscrew Mineral Cartridge from Cap A Discard Cartridge 4 Install new Cartridge onto Cap Note The unit may take several minutes to cre...

Страница 13: ...ria These microorganisms may become airborne TO CLEAN BASE 1 Turn humidifier Off and unplug Warning Do not submerge humidifier top in water 2 Remove Water Tank by lifting up To easily remove the Mist...

Страница 14: ...d air 4 Reinstall grille and twist grille clockwise until screw holes align Replace screw TO CLEAN MIST OUTLET MIST TUBE While you have the humidifier disassembled if needed rinse the Mist Outlet and...

Страница 15: ...d 1 gallon water Fill Base with solution wet all surfaces Let stand 20 minutes then empty 2 Rinse Base with water until bleach smell is gone Dry with clean cloth or paper towel 3 You may also wipe dow...

Страница 16: ...r Vornado Ultrasonic Whole Room Humidifier operates If you operate your humidifier continuously which is recommended to maintain humidity all day it may need to be refilled with water every day Check...

Страница 17: ...et point When set humidity level is reached the unit will not produce mist until humidity level in the room drops below humidity set point Airflow is blocked Remove obstruction Unit settings are too l...

Страница 18: ...duct modification repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties Th...

Страница 19: ...CL3 0683 R V04 Vornado Air LLC 415 East 13th Street Andover Kansas 67002 800 234 0604 vornado com...

Отзывы: