background image

11

English

HIGH

 

O

peration for fast humidification of larger rooms. High-speed 

operation will evaporate approximately 2 gallons of water in 24 
hours of continuous operation. (This assumes room conditions of 

70º F and 30% relative humidity.) 

LOW 

Operation for quiet, nighttime use or smaller rooms. On Low 

operation, your humidifier may run without refilling for extended 

periods. 

AUTO

Operation for more precise humidity control. Fan speed and mist 
output will fluctuate to better maintain set humidity level with the 

minimal amount of fan noise. While in Auto, you will only be able 

to mode through humidity settings (40% - 60%). Continuous will be 

disabled.

HUMIDITY – 40%–60% OR CONTINUOUS

Set the humidity level by pressing the HUMIDITY button until 
the desired humidification level is illuminated. The humidifier will 

operate until the desired humidity level is reached. At this point, 
the mist and fan will turn off. If the mist and fan do not turn on, 
the humidity setting may be lower than the room humidity level. 
Increase the humidity set point until the mist and fan turn on. This is 
an indication of the level of humidity already in the room. While in 

Continuous, you will only be able to mode through High and Low 

fan speeds before unit powers off. Auto mode will be disabled.

HOW TO USE

1.

 

Position humidifier to not blow directly on objects or plants. Plug 

power cord into standard grounded wall outlet. Remove tape from 

top of mist outlet prior to turning humidifier on.

2.

 

To turn humidifier on, press Power Button. The indicator lights 

for HIGH fan speed, 50% humidity will illuminate. After first use, 
humidity setting is saved when powered off. Fan speed will default 
to HIGH. If unit is unplugged, during next use, settings will default 
to HIGH fan speed, 50% humidity.

3.

 

Use Power Button to select HIGH or LOW fan speed or AUTO 

mode until the desired setting is illuminated.

4.

 

The humidifier will shut off when it is out of water. Refill with cool 

water and resume operation.

Note:

 Lower humidity control settings or turn off humidifier if moisture 

forms on walls or windows.

Содержание UH100

Страница 1: ...model UH100 ULTRASONIC WHOLE ROOM HUMIDIFIER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS vornado com...

Страница 2: ...2 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right...

Страница 3: ...tant Safety Instructions 4 Getting Started 7 Features 8 Controls 9 Filling Water Tank 10 How To Use 11 Mineral Cartridge 12 Automatic Refill Program 12 Cleaning 13 Storage 16 Troubleshooting 17 Warran...

Страница 4: ...or unstable surface or near water The appliance power supply power cord and plug cannot come into contact with water Do not use this product on wet surfaces Do not use this product in a bathtub or sh...

Страница 5: ...f time or during electrical storms Electric shock can occur when liquid comes in contact with electricity Be careful when removing the water tank and refilling to avoid electric shock Do not pour wate...

Страница 6: ...erence will not occur in a particular installation If this product does cause harmful interference to radio or television reception which can be determined by turning the product off and on the user i...

Страница 7: ...ning of each season the humidifier equipped with a humidistat may run constantly for a day or so and thus evaporate large quantities of moisture When the home and its furnishings have absorbed moistur...

Страница 8: ...ransducer POWER HEAD Powerful motor circulates humidified air throughout whole room MIST TUBE Guides the mist from inside the humidifier to the mist nozzle AIR OUTLET GRILLE Initiates Vornado s signat...

Страница 9: ...to select the fan speed Offers HIGH LOW or AUTO speed selection HUMIDITY Control humidity level at 40 60 or allow unit to run continuously POWER BUTTON Easily operate with power switch that turns the...

Страница 10: ...not twist tank while still in base or Cap may disengage and leak 3 Turn the Water Tank upside down and remove the Cap by turning it counterclockwise B 4 Gently place Water Tank on a flat surface and...

Страница 11: ...turn on the humidity setting may be lower than the room humidity level Increase the humidity set point until the mist and fan turn on This is an indication of the level of humidity already in the roo...

Страница 12: ...Water Tank See FILLING WATER TANK for instructions 2 Unscrew Cap 3 Unscrew Mineral Cartridge from Cap A Discard Cartridge 4 Install new Cartridge onto Cap Note The unit may take several minutes to cre...

Страница 13: ...ria These microorganisms may become airborne TO CLEAN BASE 1 Turn humidifier Off and unplug Warning Do not submerge humidifier top in water 2 Remove Water Tank by lifting up To easily remove the Mist...

Страница 14: ...d air 4 Reinstall grille and twist grille clockwise until screw holes align Replace screw TO CLEAN MIST OUTLET MIST TUBE While you have the humidifier disassembled if needed rinse the Mist Outlet and...

Страница 15: ...d 1 gallon water Fill Base with solution wet all surfaces Let stand 20 minutes then empty 2 Rinse Base with water until bleach smell is gone Dry with clean cloth or paper towel 3 You may also wipe dow...

Страница 16: ...r Vornado Ultrasonic Whole Room Humidifier operates If you operate your humidifier continuously which is recommended to maintain humidity all day it may need to be refilled with water every day Check...

Страница 17: ...et point When set humidity level is reached the unit will not produce mist until humidity level in the room drops below humidity set point Airflow is blocked Remove obstruction Unit settings are too l...

Страница 18: ...duct modification repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties Th...

Страница 19: ...CL3 0683 R V04 Vornado Air LLC 415 East 13th Street Andover Kansas 67002 800 234 0604 vornado com...

Отзывы: