The 

Boiler

 (1) is the internal heating chamber where water is converted into steam.  Some   

   empty space inside the 

Boiler

 is required for this conversion process, so the recommended 

   maximum water capacity (33 oz. / 975 ml.) should not be exceeded when filling with water.

 

The 

Boiler Fill Hole

 (1

a

) is the opening through which water is poured into the 

Boiler

.

 

The 

Boiler Cap

 (1

b

) securely covers the 

Boiler Fill Hole

, preventing hot steam from escaping the

   Boiler

.  The 

Boiler Cap

 must be unscrewed and removed in order to fill the 

Boiler

 with water.

 

The 

Heating Indicator Light

 (2) illuminates to indicate that the unit is powered on and actively

   heating, and deactivates when the unit is ready to begin steaming.

 

The two 

Strap Tabs

 (3) serve as connection points for connecting the 

Shoulder Strap

 to the unit.

 

The 

Main Steam Nozzle

 (4) releases a flow of hot, penetrating steam when the 

Steam Trigger

 is

   pressed.  The 

Jet Nozzle

 and 

Extension Wands

 connect directly to the 

Main Steam Nozzle

.

 

The 

Steam Trigger

 (5) controls the flow of steam from the 

Main Steam Nozzle

.

 

The 

Steam Lock Switch

 (5

a

) locks down the 

Steam Trigger

 for a continuous flow of steam.

 

The 

Steam Hose

 (6) directs steam from the 

Boiler

 to the 

Main Steam Nozzle

, and is designed to

   remain flexible while safely containing the steam.

 

The 

Extension Wands

 (7) connect to the 

Main Steam Nozzle

, allowing easier cleaning of floors,

   ceilings and other hard-to-reach places.

 

The 

Utility Head

 (8) connects to the 

Jet Nozzle

 and is designed for cleaning floors and other 

   large surface areas.  The 

Utility Head

 includes three modes of operation:  brush, squeegee, and   

   neutral (flat).  Refer to Page 8 for details.

 

The 

Cloth Cover

 (9) wraps around the 

Utility Head

, diffusing steam flow for more effective 

   cleaning on tile, hardwood and other hard surface floors.

 

The 

Shoulder Strap

 (10) connects to the two 

Strap Tabs

, allowing the unit to be conveniently 

   toted hands-free for mobile cleaning.

 

The 

Jet Nozzle

 (11) connects to either the 

Main Steam Nozzle

 or the 

Extension Wands

, and is

   designed to safely focus the flow of steam.  The 

Utility Head

Brushes

 and 

Nozzle Tip

 all

   connect to the 

Jet Nozzle

.

 

The 

Nylon Brush

 (12) connects to the 

Jet Nozzle

 and is designed to work with steam to remove

   stubborn stains and grime. It is ideal for use on tile, grout, carpet, upholstery, and any other

   surface that will not be scratched or damaged by the nylon bristles.

 

The 

Brass Brush

 (13) connects to the 

Jet Nozzle

 and is designed to work with steam to remove

   stubborn stains and grime.  It is intended for use on BBQ grills, oven racks, automobile engines 

   & wheels, shop tools and other hard metal surfaces

   NOTE: Some delicate surfaces, such as stainless steel, may be scratched or damaged by  

   the brass bristles.  Use careful judgement when deciding what surface to clean with the 

   Brass Brush. If you are unsure if a surface will be damaged, it is recommended that you 

   carefully test a small inconspicuous spot before proceeding.

 

The 

Nozzle Tip

 (14) connects to the 

Jet Nozzle

 and is designed to finely focus the flow of  steam.

   It is recommended that the 

Nozzle Tip

 be used when not using either of the 

Brushes

 or the

   

Utility Head

 with the 

Jet Nozzle

.

 

The 

Measuring Cup

 (15) is provided to assist in easily and consistently filling the 

Boiler

 with the 

   optimum amount of water (33 oz. / 975 ml.).

Содержание SF-246

Страница 1: ...Please read all instructions before use KEEP YOUR RECEIPT FOR WARRANTY PURPOSES User s Guide Portable Steam Cleaner MODEL SF 246...

Страница 2: ...er cord as handle let it hang over edges of counters or be crimped or closed in doors 6 Never yank power cord to disconnect from outlet instead grasp plug and pull to disconnect 7 Do not operate unit...

Страница 3: ...sed other cleaning agents could damage unit or cause injury Distilled or de mineralized water is highly recommended in order to minimize potential build up of mineral deposits 17 To reduce risk of con...

Страница 4: ...ing Indicator Light Strap Tabs Main Steam Nozzle Steam Trigger Steam Lock Switch Steam Hose Extension Wands 2 Utility Head Cloth Cover Shoulder Strap Jet Nozzle Nylon Brush Brass Brush Nozzle Tip Meas...

Страница 5: ...Head includes three modes of operation brush squeegee and neutral flat Refer to Page 8 for details The Cloth Cover 9 wraps around the Utility Head diffusing steam flow for more effective cleaning on t...

Страница 6: ...t button snaps through hole on Jet Nozzle FIGURE 1 B 3 To remove press in on locking button while simultaneously pulling Jet Nozzle off of Main Steam Nozzle CONNECTING BRUSHES NOZZLE TIP NOTE Nozzle T...

Страница 7: ...180 to secure it to Utility Head FIGURE 3 C NOTE Jet Nozzle will NOT lock into position and can still be freely rotated However it will not disconnect from Utility Head unless turned back a full 180 4...

Страница 8: ...ile continuing to hold button down slide Extension Wand onto nozzle Push wand over button and continue to push it on until button snaps through hole on Wand FIGURE 4 B 3 Now slide second Extension Wan...

Страница 9: ...r is machine washable To avoid picking up lint washing separately from other fabrics is recommended Only use liquid detergent Avoid using any fabric softeners or bleach Air drying is recommended machi...

Страница 10: ...er to Page 13 for more information about mineral build up 6 Carefully pour water from Measuring Cup into Boiler through Boiler Fill Hole 7 If desired refill Measuring Cup to maximum fill line with wat...

Страница 11: ...own the trigger to lock it down FIGURE 8 This will allow a continuous flow of steam without the need of holding down the Steam Trigger manually 5 Using a slight back and forth motion over the area you...

Страница 12: ...al build up may limit the effectiveness and reduce the life of your Portable Steam Cleaner The best way to minimize mineral build up is to use distilled or de mineralized water when using your Portabl...

Страница 13: ...ssistance contact a licensed electrician Immediately cease usage and unplug Immediately cease usage and unplug Refer to Refilling procedure on Page 10 Refer to Filling with Water procedure on Page 10...

Страница 14: ...IN APPROXIMATE 30 MIN APPROXIMATE 6 80 LBS 3 08 KG 13 98 35 5 CM x 6 89 17 5 CM x 8 66 22 0 CM 12 8 390 0 CM MODEL VOLTAGE WATTAGE WATER CAPACITY HEATING TIME CONTINUOUS STEAM TIME UNIT WEIGHT UNIT DI...

Страница 15: ...ENGLISH 15...

Страница 16: ...iew this product online eval e este producto en l nea valuer ce produit en ligne www steamfast com reviews Steamfast 415 East 13th Andover KS 67002 1 800 711 6617 www steamfast com consumerservice ste...

Отзывы: