STD 420-0003

  

 

Volvo Group 

 

Version 

Page

 
 

4 Apparatus 

4.1 General 

The equipment shall comply with the dimensional requirements specified in ISO 6452. Alternative equipments are 
permitted provided it has been ascertained that they give the same result as equipment complying with ISO 6452. 

Evaluation of alternative equipment shall be made by testing, and it shall be possible to give an account of the 
result in accordance with sections 6.1.3 and 6.2.3. In order to comply with the requirements, the test results must 
be within the specified tolerances. 

4.2 Thermostatically controlled bath, 

designed to operate up to 130 °C. Safety devices shall be fitted to prevent 

overheating. The circulation system, the bath capacity and the heating system shall be such that the temperature 
can be kept constant to within ± 0,5 °C throughout the bath. 

Note 1: It is very important to maintain a stable temperature, as tests have shown that even as slight a difference 
as 0,5 °C does show in the test results. 

The bath shall be designed so that, after placing the beakers in the bath, the temperature does not drop more than 5 °C, 
and the test temperature is regained after no more than 10 min. The minimum distance between the beakers and 
the walls shall be 30 mm and between the bottom of the bath and the beakers 60 mm.  

The bath shall be equipped with a device indicating the distance between the bath fluid and the lower surface of the 
glass plate. This distance shall be 60 ± 2 mm. 

Note 2: Some heaters/circulators have a centrifugal pump in the bottom pumping the liquid at high speed around 
the bath. The beakers will have the liquid passing them at different speeds and this will cause different 
temperatures in the different beakers

4.3 Cooling plates, 

designed to be placed on the glass plates to keep them cool. The cooling plates shall be 

hollow and made of corrosion-resistant metal, with the side facing the glass plate made of aluminium. They shall 
have two cooling-water connections located so that the cooling water flows through the whole of the interior of the 
plate. The surface in contact with the glass plate shall be flat. The mass of a cooling plate filled with water shall be 
at least 1 kg, to overcome the buoyancy of the beaker in the bath. The whole of the weight of the cooling plate shall 
rest on the beaker. A separate cooling plate shall be used for each beaker. 

The cooling plates and the associated water thermostat shall be designed so that the mean water temperature is 
21 °C and the difference in temperature between the inlet and outlet does not exceed 1 °C. 

4.4 Flat-bottomed beakers, 

of heat-resistant glass, minimum mass 450 g, with the dimensions shown in Figure 1.  

4.5 Metal rings, 

external diameter 80 mm, internal diameter 74 mm, height 10 mm and mass 55 ± 1 g, made of 

corrosion-protected steel, to keep the test pieces flat.  

4.6 Sealing rings, 

of fluoro-rubber or silicone rubber with L-shaped or circular cross-section, inner diameter 90-

95 mm, thickness 2-4 mm and hardness 50-70 IRHD.  

4.7 Float-glass plates, 

of residential or windshield window quality for condensation of the fogging, thickness 

3 ± 0,2 mm, either square with minimum dimensions of 110 x 110 mm or circular with a diameter of 103 mm. The 
reflectometer values of all the plates used shall be the same to within ± 2 % units. The tin and non-tin surfaces of 
the plates shall be identified. 

 

NOTE - The tin and non-tin surfaces of the glass plates can be identified by viewing the surfaces in a darkened 
room under UV light at 254 nm wavelength. The tin surface will fluoresce when exposed to the UV light.

 

 

4.8 Filter paper

, with a diameter of 110 mm and a mass per unit surface area of 90 g/m

2

.

 

Содержание STD 420-0003

Страница 1: ...neral 4 2 Thermostatically controlled bath 4 3 Cooling plates 4 4 Flat bottomed beakers 4 5 Metal rings 4 6 Sealing rings 4 7 Float glass plates 4 8 Filter paper 4 9 Aluminium foil 4 10 Reflector mete...

Страница 2: ...e it is the difference expressed in mg between the masses of the aluminium foil before and after testing 3 Materials 3 1 Thermal transfer fluid for the thermostatically controlled bath The fluid shal...

Страница 3: ...ooling plates designed to be placed on the glass plates to keep them cool The cooling plates shall be hollow and made of corrosion resistant metal with the side facing the glass plate made of aluminiu...

Страница 4: ...uminium foil in order to decrease the risk of their edges being uneven and damaged Great care needs to be excercised so that the aluminium foil does not get contaminated Use lint free cotton gloves or...

Страница 5: ...kaline dishwasher detergents 4 13 Balance with scale divisions of 0 01 mg 4 14 Glass plate rack 4 15 Phosphorpentoxide and silica gel 4 16 Stamping apparatus for circular test pieces 80 1 mm 4 17 Glov...

Страница 6: ...ces containing natural materials 168 h 2 h Coated fabrics 48 h 2 h Other materials 24 h 2 h 6 1 2 Cleaning 6 1 2 1 Cleaning with a dishwasher Wash the sealing rings beakers and metal rings with glass...

Страница 7: ...pe with paper If the beakers have contained greasy products or if the specimens have become damaged during the test leaving a deposit on the bottom of the beakers the beakers shall be washed in aceton...

Страница 8: ...the glass plate is placed on the sealing ring The beakers with test pieces are placed in the bath that has reached the prescribed temperature On top of the glass plate a filter paper is placed follow...

Страница 9: ...culated using the formula 1 4 4 1 2 i j i j F F s where Fi is the fogging value of each point of measuring in 4 is the number of test points on the glass plate This standard deviation indicates the ho...

Страница 10: ...DP Note It is very important not to moisten the walls of the beaker with the DIDP when handling the beaker as this will lead to a larger area with DIDP and a higher test result 6 2 4 Procedure 6 2 4 1...

Страница 11: ...is reported with an accuracy of 0 01 mg 7 Report The report shall contain Reference to this standard Reference to mehod used method F evaluation of fogging using a glossmeter or method G gravimetrica...