![Volvo Penta TAD1242GE Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/volvo-penta/tad1242ge/tad1242ge_technical-description_1048994051.webp)
60
Group 23 EDC III
Electronic fault detection
Overload test on stator
1.
Set the multimeter for diode measurement.
2.
Connect the test probes between the stator body
and one of the three stator windings.
3.
The instrument should read OL.
If any other value is shown, the stator is short-cir-
cuited.
Checking stator windings
1.
Set the multimeter for diode measurement.
2.
Connect the test probes between the phase con-
nections.
3.
Take three readings.
4.
The instrument should show the same value for
all three readings.