20
Group 23 EDC III
Gränsvärden
Limit values, electronic control unit (ECU) TWD1240VE
Alarm limits:
Coolant temperature:
Alarm lamp lights
Engine is switched off
Engine output 50%
Standard value Volvo Penta
98°C / 208°F
100°C / 212°F
Parameter setting (can be
set by the customer)
95–101°C / 203-214°F +2°C / 36°F over the alarm value
NOTE:
Engine protection can be switched off.
Coolant level:
Alarm lamp lights when the contact is activated
and the engine is switched off
NOTE:
Engine protection can be switched off.
Charge air temperature:
Standard value Volvo Penta
100°C / 212 °F
102°C / 216°F
NOTE:
Engine protection can be switched off.
Oil pressure:
Standard value Volvo Penta
Idle: 0.7 bar (10,2 psi) For oil pressure 0.3 bar (4,4 psi)
lower than alarm value
>1500 RPM: 2.5 bar
For oil pressure 0.3 bar (4,4 psi)
(36,3 psi) lower than alarm value
* See diagram: ”Oil pressure” below.
NOTE:
Engine protection can be switched off.
Oil temperature:
Standard value Volvo Penta
125°C / 257°F
127°C / 261°F
Parameter setting (can be
set by the customer)
120–130°C / 248-266°F
+2°C / 36°F over
alarm value
NOTE:
Engine protection can be switched off.
Fuel pressure:
Standard value Volvo Penta
<2 bar (<29 psi)
Engine not switched off
Monitor, water in fuel:
Alarm lamp lights
*Oil pressure
Alarm limit
Engine is switched off
rpm