The control unit shall be firmly fixed on a dry and easily
accessible location, e.g. inside of transom. Screws are
not included. Check that the distances from the control
unit to each of the interceptors are not too long, i.e. the
connecting cables are max 2.5 meters or 4 meters long
(8.3’ or 13.1’), depending on your choice.

Connect the 4-pole cables to the control unit. 

See fig. 1,

2 and 19

. There are two versions of the control unit, one

for 1-pair of interceptors and one for 2-pairs of
interceptors. Each control unit is equipped with four 4-
pole sockets marked P2 (port 2), P1 (port 1), SB1
(starboard 1), SB2 (starboard 2), one 6-pole socket
marked AUX and one red cable () and one
black cable (marked -) for power supply. One pair of
interceptors: use P1 for the port interceptor and SB1 for
the starboard interceptor. Two pairs of interceptors: use
P1 and P2 for the two port interceptors and SB1 and SB2
for the starboard interceptors. 

See fig. 19

.

9.

Install the control panel (B), 

see fig. 1, 3 and 20

, easily

accessible at the helm station. Hole cutting is diameter
52 mm (2”). 

See  fig. 3.

 Use the gasket, included in the

supply (

20 A

). For flush mounting of the panel,  press the

center section out  and use the rest of the gasket for
assembly 

see fig. 20 B

. See also the hole template for

the control panel.

Install the 6-pole connection cable (E) fig. 1 between the
control unit (connector marked AUX) and the control pa-
nel.

Connect the control unit power supply cables to 12V or
24V DC (red cable to plus and black cable to minus).
Protect the installation by a 6-8A fuse on the plus cable.
See wiring diagrams fig. 23 and 24.

Connect the red plus cable from the control panel to the
start lock running position.

Note!

 For Volvo Penta EVC EC engines, the red cable

must not be connected directly to the start key, but ins-
tead to the relay for external accessories. 

Note!

 Always

check with your engine supplier whether there are any
other recommendations or requirements that concern
the wiring to the start lock. Protect the installation by a 3-
8A fuse on the plus cable.

If more than one helm station is installed, only the main
station control panel (red cable) shall be connected to
the start lock or to the relay, as described above. For
mechanical governed engines as well as for Volvo
Penta EVC MC engines, see wiring diagram fig 23 and
for EVC EC engines, see wiring diagram fig 24.

If a suitable fuse box is not available in the boat, Volvo
Penta resetable 8A breaker, part No 966689, can be
used for protection of the installation. 

See fig. 21

 as well

as the section ”Component guide”.

System start up

Once the QL Boat Trim System is mechanically installed
and all electrical cables are connected, it’s time to carry
out the calibration of the system before the system can
be operated. This is done in order to determine the
blade position when fully retracted and fully out
respectively. The calibration is performed as follows:

1.
Turn on the main switch.

2.
Press the upper and lower button on the control panel
simultaneously and keep them in.

3.
Turn the start key to running position (without starting the
engine).

4.
Wait minimum 10 sec. until the interceptor blades start to
move out and then release the panel buttons. The
blades may start moving before the 10 sec. have
passed, however the upper and lower buttons must still
be pressed down, until at least 10 sec. have passed.

5.
The blades will go fully out, stop and then retract fully.
Once this has be done in a proper way, the two upper
and two lower LEDS on the control panel will flash twice.

See fig. 22

.

Fig. 19

Fig. 21

Fig. 22

Содержание QL Boat trim system

Страница 1: ...ctions QL Boat trim system User installation Instructions QL Boat trim system User installation Instructions QL Båttrimsystem User installation Instructions QL Boat trim system User installation Instructions QL Boat trim system User installation Instructions QL Boat trim system ...

Страница 2: ...rkstäder som har personal med kvalificerad fackutbildning Monteringsanvisningen är enbart framtagen för yrkesbruk och är inte avsedd för icke yrkesmässig användning Volvo Penta påtager sig inget som helst ansvar för eventuella skador såväl materiella som personskador som kan bli följden om monterings anvisningen ej följs eller om arbetet utförs av icke yrkeskunnig personal VIGTIGT Dette sæt med ti...

Страница 3: ...CONTENT Presentation of the QL BoatTrim System 2 Sizing guidelines 3 Component guide 4 Installation of the QL BoatTrim System 5 System start up 8 Operating the system 9 Error codes 10 Maintenance 10 ...

Страница 4: ...tem The panel is also equipped with two rows of LEDs for exact trim indication Length Width Height Hole cutting mm inch mm inch mm inch mm inch 83 3 3 68 2 7 13 0 5 52 2 0 Surface mounted see fig 20 A Interceptor unit C Two different sizes are available Length Width Height mm inch mm inch mm inch 300 11 7 100 3 9 42 1 7 450 17 7 100 3 9 42 1 7 Outside transom Each interceptor unit is supplied with...

Страница 5: ... 100 mm 3 9 42 mm 1 7 Sizing guide lines Many factors affect the choice of properly sized trim unit configurations and the ultimate responsibility for selection is up to the boat owner boat builder These sizing recommendations are based on average boat performance Your choice may vary based on power engine configuration weight distribution type of boat and use When making a choice please remember ...

Страница 6: ... 874779 5 m 874780 7 m 874781 9 m 874782 11 m 874783 Control unit 1 pair 1140718 1 1 1 1 Control unit 2 pairs 1140719 1 1 1 1 1 1 4 pole cable 2 2 4 4 4 2 2 4 4 4 2 5m 3817171 4 0m 3817172 Interceptor unit 300mm 12 1140714 2 2 4 2 2 4 Interceptor unit 450mm 18 1140712 2 2 4 2 2 4 Optional component Resettable 966689 2 2 2 2 2 2 2 2 2 2 breaker 8A Note For each extra helm station max 4 helm station...

Страница 7: ...l Position the interceptor min 50 mm 2 from the chine and run towards the centerline of the boat Boats with Outboard Motors Inboard Outboard I Os or Water Jet installation must maintain a minimum of 200 mm 8 from the centerline of the actual drive unit to the closest edge of the interceptor units See fig 7 Boats with inboard motors may utilize the entire run of the transom still leaving min 50 mm ...

Страница 8: ...e 32 mm 1 1 4 hole through transom using a high quality hole cutter Note Only use a hole cutter of 32 mm 1 1 4 no other diameters of the tool is accep ted Note Machine the hole perpendicular to the tran som surface vertically as well as horizontally see fig 14 and 15 Note To check whether the tool you are go ing to use really will end up in the correct hole diameter make a test hole in a piece of ...

Страница 9: ...see sealant specification on the grommet flange flange towards the transom see fig 16 and push pull the grommet into the hole Press it towards the transom and adjust it so the two flange holes fit to the pre drilled holes in the transom Screw up the grommet use the two small screws as supplied and tighten Remove any residual sealant before it s harde ned Push the cable from inside so that the plug...

Страница 10: ...unning position Note For Volvo Penta EVC EC engines the red cable must not be connected directly to the start key but ins tead to the relay for external accessories Note Always check with your engine supplier whether there are any other recommendations or requirements that concern the wiring to the start lock Protect the installation by a 3 8A fuse on the plus cable If more than one helm station i...

Страница 11: ...ntrol panel has four buttons The upper button lowers the blades in paralell bow down The lower button retracts the blades in parallell bow up The left button lowers the starboard blade and retracts the port blade tilt port The right button lowers the port blade and retracts the starboard blade tilt starboard The blade operation starts when pressing the button and stops when releasing it The LED s ...

Страница 12: ...on starboard side are flashing Error Indicates that the interceptor blade s on starboard side are stuck and can not reach the correct position Action Check so that the interceptor blade s are not stuck due to marine growth dirt mechanical damage etc Clean replace them if neccessary EC 6 Flashing The two upper green LEDs are flashing Error Indicates that there is no communication between the contro...