background image

   

 

 

 

Table Of Contents 

 

 

1. Safety ............................................................................................................................... 1

 

1.1 Important Safety Instructions ..................................................................................... 1

 

1.2 EMC .......................................................................................................................... 1

 

1.3 Installation information .............................................................................................. 1

 

1.4 Maintenance ............................................................................................................. 2

 

1.5 Recycling the used battery ......................................................................................... 2

 

2 Operation & structure .......................................................................................................... 3

 

3.      Installation .................................................................................................................... 4

 

3.1      Mechanism and Exterior ......................................................................................... 4

 

3.1.1    Mechanical Data ............................................................................................ 5

 

3.1.2    Other Views .................................................................................................. 6

 

3.2        Internal Mechanisms ............................................................................................ 8

 

3.2.1    Input and Output Breakers ............................................................................. 8

 

3.2.2    Wiring Terminal Block .................................................................................... 9

 

3.2.3    Modules ...................................................................................................... 10

 

3.3        Control Panel & interface .................................................................................... 11

 

3.3.1    LED indications ............................................................................................ 11

 

3.3.2    LCD Display ................................................................................................. 11

 

3.3.3    Function Keys .............................................................................................. 12

 

3.4      Installation and Wiring ......................................................................................... 12

 

3.4.1    Before Installation ....................................................................................... 12

 

3.4.2    Installation Environment .............................................................................. 12

 

3.4.3    Transportation ............................................................................................. 13

 

3.4.4    Unpacking ................................................................................................... 14

 

3.4.5    Positioning .................................................................................................. 15

 

3.5        Modules ............................................................................................................ 15

 

3.5.1    Power Module .............................................................................................. 15

 

3.5.2    Install a Power Module ................................................................................. 16

 

3.5.3    Remove a Power Module .............................................................................. 17

 

3.5.4    STS Module ................................................................................................. 17

 

3.5.5    Remove the STS Module .............................................................................. 18

 

3.5.6    Install Battery .............................................................................................. 18

 

3.6        Power Cable ...................................................................................................... 19

 

3.6.1    AC input and output maximum current and power cable configuration. ........... 20

 

3.6.2    DC input maximum current and power cable configuration. ............................ 20

 

4. Control Panel and Display Description ............................................................................... 21

 

4.1 Introduction ............................................................................................................ 21

 

4.2 Screen Description ................................................................................................... 23

 

4.2.1 Start Screen .................................................................................................. 23

 

4.2.2 Main Screen ................................................................................................... 23

 

4.2.3 Menu Screen ................................................................................................. 24

 

4.2.4 Control Screen ............................................................................................... 24

 

4.2.5 Measurement Screen ...................................................................................... 25

 

4.2.6 Setup Screen ................................................................................................. 27

 

Содержание +Power 30U-120

Страница 1: ...Modular Online UPS Uninterruptible Power Supply System Version 1 2 User Manual...

Страница 2: ...Wiring 12 3 4 1 Before Installation 12 3 4 2 Installation Environment 12 3 4 3 Transportation 13 3 4 4 Unpacking 14 3 4 5 Positioning 15 3 5 Modules 15 3 5 1 Power Module 15 3 5 2 Install a Power Mod...

Страница 3: ...eplacement Procedures Of Power Module STS Control Module And Battery Module 49 6 1 1 Notes 49 6 1 2 Power Module Replacement Procedures 49 6 1 3 STS Control Module Service Procedures 50 6 1 4 Battery...

Страница 4: ...ce personnel only 1 2 EMC WARNING This is a product for commercial and industrial application in the second environment installation restrictions or additional measures may be needed to prevent distur...

Страница 5: ...rce of the ground Contact with any part of a grounded battery can result in electrical shock The likelihood of such shock is reduced if such grounds are removed during installation and maintenance Whe...

Страница 6: ...3 2 Operation structure Figure 2 1 Wiring diagram for dual inputs Figure 2 2 Wiring diagram for single input...

Страница 7: ...are an STS Module 1 8 Power Module slots and Battery modules All wiring terminal blocks are allocated in the back of system The side panels are lockable The casters at the bottom of the UPS cabinet c...

Страница 8: ...5 3 1 1 Mechanical Data Dimensions UPS cabinet Width Depth Height 30 90Kw 30U 600mm 1100m 1475mm 30 210Kw 42U 600mm 1100m 2010mm Figure 3 2 Dimensions...

Страница 9: ...or to see STS Module Switch unit Power Module and Battery Module Rear View Unlock and open the rear door to see Battery Breaker Rear View Front View 1 Switch unit 2 Bypass module 3 Power module 4 Batt...

Страница 10: ...to have battery module for Standard Series Please consider the external battery space and wiring gauge for Extended Series Standard Series Extended Series Photo Cabinet Height 30U 42U 30U 30U 42U Swi...

Страница 11: ...er and input output wiring terminal block Please refer to the following sections 3 2 1 Input and Output Breakers Open front and back door The Input Breaker Bypass Breaker and Output Breaker are locate...

Страница 12: ...ds Includes R S T and Neutral terminals Bypass Input Block Connects bypass AC source Includes R S T and Neutral terminals Main Input Block Connects main AC source Includes R S T and Neutral terminals...

Страница 13: ...ntrol power communication circuits an internal Static Transfer Switch and a fuse Power Module Each power module capacity is 30kVA 30kW It includes a power factor correction rectifier a battery charger...

Страница 14: ...ED indications LED Color Status Definition INPUT Green On Input source is normal Flashing Input source is abnormal Off No input source BYPASS Green On Load on Bypass Flashing Input source is abnormal...

Страница 15: ...n routes e g corridor door gate elevator etc and installation area can accommodate and bear the weight of the UPS the external battery cabinet and handling equipment Ensure that the installation area...

Страница 16: ...riate equipment like a forklift Do not use the UPS casters to move the over a long distance After the UPS has been removed from the pallet to ground we suggest that at least three people move the UPS...

Страница 17: ...maged please immediately notify the carrier 3 4 4 1 System Packaging 1 Use a forklift to move the product to installed area Refer to Figure 3 9 2 Please remove 5 boards in order from 1 to 5 as shown i...

Страница 18: ...el heat produced by UPS protection against atmospheric agents protection against excessive humidity and high heat sources protection against dust compliance with the current fire prevention requiremen...

Страница 19: ...mal operation of the slave UPS 3 5 2 Install a Power Module Follow below procedures to install the power module 1 Use the DIP switch on the front panel of each Power module to set the module address T...

Страница 20: ...o the position i e in ready state 3 5 3 Remove a Power Module Warning Before removing any Power Module make sure the remaining Power Modules can support the critical loads 1 Turn the ready switch to t...

Страница 21: ...UPS is in Bypass Mode cutting off the bypass AC source will terminate power supply to the critical loads 5 The STS Module is heavy 30 kg At least two people are required for handling Please follow th...

Страница 22: ...apacity and maximum charging current in LCD setting Otherwise if battery setting is different from real installation the UPS will keep warning Please refer to section 4 2 6 3 and Table 5 17 for the de...

Страница 23: ...r the max current and wiring gauge as possible for future extension 3 6 2 DC input maximum current and power cable configuration For standard series in 30U cabinet battery inside Model 30KVA 60KVA 90K...

Страница 24: ...all measured parameters UPS and battery status and alarms The control panel and display description is divided into three functional areas 1 LCD display 2 LED indications 3 Control keys 4 Audio Alarm...

Страница 25: ...nction key table Control Key Description Esc Return to previous screen or cursor displacement When screen is in Main screen it will enter setting menu by pressing ESC key Up Left Key for menu page nav...

Страница 26: ...gure 4 2 Figure 4 2 Initial screen 4 2 2 Main Screen After initialization the main screen will display as Figure 4 3 Main screen is divided into five parts 1 UPS Mode Current Operation Mode 2 UPS Flow...

Страница 27: ...ss ENTER to enter into the sub screen as shown in Figure 4 4 and 4 5 Figure 4 4 Menu tree Figure 4 5 Menu screen 4 2 4 Control Screen Use UP and DOWN buttons to choose CONTROL option and press ENTER b...

Страница 28: ...mmand or choose NO to cancel command as shown in Figure 4 8 Figure 4 8 Yes or No screen 4 2 5 Measurement Screen Use UP and DOWN buttons to choose MEASUREMENT option Choose module ID number to measure...

Страница 29: ...1V Frequency Hz Bypass Frequency L1 L2 L3 Units 0 1Hz Power Factor Bypass Power Factor L1 L2 L3 Load Sout KVA Apparent power Units 0 1KVA Pout KW Active power Units 0 1KW Load Level The percentage of...

Страница 30: ...ord to access General SYSTEM and BATTERY sub menus as shown in Figure 4 11 4 12 and 4 13 Figure 4 11 Setup menu It s required to enter 4 digit password to enter SETUP menu If incorrect password is ent...

Страница 31: ...Y Y Y Y Factory Reset Y EEPROM Reset Y EPO Function Y Save Setting Y Y Output Voltage Y Y Bypass Voltage Range Y Y Y Y Y Y Y Y Bypass Frequency Range Y Y Converter Mode Y ECO Mode Y Y Y Y Bypass Mode...

Страница 32: ...an be set in this operation mode 4 2 6 1 Setup General Screen Use UP and DOWN buttons to choose between different sub menus and press ENTER button to enter into the GENERAL setting screen as shown in...

Страница 33: ...m Last Maintain Date Set system latest maintenance date yyyy mm dd Battery Installed Date Set battery installed date yyyy mm dd Battery Last Maintain Date Set battery latest maintenance date yyyy mm d...

Страница 34: ...n in Figure 4 16 System setting can be set only when UPS is operated in certain mode Please check setting item availability table 4 5 for the details If it s not set up under specific mode the warning...

Страница 35: ...mode Disable or Enable Auto Restart Set auto restart Disable or Enable After Enable is set up once UPS shutdown occurs due to low battery and then utility restores the UPS will return to line mode Co...

Страница 36: ...wn in below chart Cold Start Button Step 2 After pressing Cold Start Button UPS will enter Standby mode Refer to below chart for LCD display Step 3 Before UPS enters shutdown mode please press Power O...

Страница 37: ...ns to switch different sub menus Press ENTER button to enter into the BATTERY setting screen as shown in Figure 4 18 Battery setting can be set only when UPS is operated in standby mode If it s not in...

Страница 38: ...n in battery mode 10 50 BATTERY TEST Periodic Battery Test Set periodic battery test Disable or Enable Battery Test Interval Set battery test interval 7 99 Days Stop by Time Set testing time for batte...

Страница 39: ...llel Screen Use UP and DOWN buttons to switch different sub menus Press ENTER button to enter into the Parallel setting screen as shown in Figure 4 20 Parallel setting can be set only when UPS is oper...

Страница 40: ...ck the UPS configuration of the unit and INFORMATION divided into Identification System and Battery as shown in Figure 4 21 4 22 4 23 4 24 and 4 25 Figure 4 21 Information menu Figure 4 22 Information...

Страница 41: ...nts Screen When event occurs you will see flashed warning text in the Main Screen as shown in Figure 4 26 Besides you also can enter the EVENTS Menu to check the latest event lists and history events...

Страница 42: ...efore if it exceeds more than four you have to press UP or DOWN button to read other event as shown in Figure 4 29 Figure 4 29 Current Events screen 4 2 8 2 History Events It saved detailed informatio...

Страница 43: ...nter 4 digit password to enter Reset All Events screen as shown in Figure 4 31 Then use LEFT and RIGHT buttons to choose YES or NO Choose YES and press ENTER button to reset all events or choose NO to...

Страница 44: ...ltage within specified duration Fault Inverter Voltage Over Inverter Voltage over Peak Value Fault Inverter Voltage High Inverter Voltage is too high Fault Inverter Voltage Low Inverter Voltage is too...

Страница 45: ...ive Check the EPO connector Warning Over Load Fail The load devices are demanding more power than the UPS can supply Line mode will transfer to Bypass mode Warning Communicate CAN Fail CAN communicati...

Страница 46: ...gure error Pre Alarm Line Voltage Fail Line voltage over range Pre Alarm Line Voltage Normal Line voltage recovered to normal Pre Alarm Line Frequency Unstable Line frequency over range Pre Alarm Line...

Страница 47: ...nce Bypass Switch State Port X5 Internal Output Switch State Port reserved function reserved function X6 Battery Cabinet Temperature Detection Port reserved function X7 Bypass back feed Control Port r...

Страница 48: ...verters and static transfer switch But it does not internally disconnect the input power supply 2 The default setting of the EPO function logic is Normal Opened N O 5 2 BCB Port This function is reser...

Страница 49: ...e 5 4 This function is reserved Figure 5 5 Internal Output Switch State Port Table 5 4 Description of Internal Output Switch State Port Name Position Description Internal Output Pin1 X5 1 Internal Out...

Страница 50: ...nication SCL Signal SDA X6 2 I C communication SDA Signal 3 0V X6 3 3V Power GND X6 4 GND 5 6 Bypass back feed Control Port This function is reserved Figure 5 7 Bypass back feed Control Port Table 5 6...

Страница 51: ...l Port Name Position Description Pin1 X8 1 Reserved Pin 2 X8 2 Reserved 5 8 Other Communication Interface The RS232 port and USB Port can use in UPS commissioning and service or monitor the Ups inform...

Страница 52: ...in 10 minutes after they are removed 6 1 2 Power Module Replacement Procedures Confirm UPS is in normal mode and bypass function source is available 1 Enter to menu control Turn To Bypass YES on the o...

Страница 53: ...en the module is pulled out of the cabinet halfway At this point you must press the metal safe locker before you continue to pulling the module out Please refer to below illustration 4 After servicing...

Страница 54: ...nt door Each filter is fixed by a fixing bar on both sides The air filter replacement procedures are as follows 1 Open the front door of the UPS to reveal the air filters on the back of the door 2 Rem...

Страница 55: ...4 2 Level 3 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 3 Surge IEC EN 61000 4 5 Level 3 CS IEC EN 61000 4 6 Level 3 Power Frequency Magnetic field IEC EN 61000 4 8 Level 3 Low Frequency S...

Страница 56: ...0 Dimensions W x D x H mm 600 x 1100 x 2010 Weight kg 932 549 Color N A Black Protection degree IEC 60529 N A IP20 front door and back door is open or closed 7 4 Electrical Characteristics Input Recti...

Страница 57: ...charge mode Floating Voltage 2 3V cell Boost charging 2 35V cell Battery charging power1 max current A 8 per power module adjustable Note 1 At low input voltage the UPS recharge capability increases...

Страница 58: ...Overload 105 110 for 60min 110 120 for 10min 121 150 for 1min 150 for 200ms Upstream protection bypass line N A Circuit breaker rated up to 100 of nominal output current Current rating of neutral cab...