![Voltronic Power Axpert Plus Duo Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/voltronic-power/axpert-plus-duo/axpert-plus-duo_user-manual_1047785016.webp)
14
70A
80A
90A
100A
110A
120A
130A
140A
150A
160A
170A
180A
190A
200A
210A
220A
230A
240A
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
04
Power saving mode
enable/disable
Saving mode disable
(default)
If disabled, no matter connected load
is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 26,
27 and 29.