The two 120V receptacles are rated at 20 and 30 amps respectively.Should
.3 Voltage Selection Switch
generator
. If you operate the generator with the
switch in this position, the electric current is limited to 15 amps to the 120V
receptacles although it can prov
ps at 240V from the 120/240V
. Total current is limited to 45.8 amps at rated
ad.
this current be exceeded, the circuit protection device willactivate and cut
allcurrent to the receptacle. This will be indicated by the push button popping
out. Reduce the load to the receptacle and reset the circuit protector by
pushing in the button.
5
The voltage selection switch has two positions: AC120V and AC120/240V.
1. When the voltage selection switch is in the 120/240V position, the
supplies both 120V and 240V AC power
ide 15 am
receptacle.
2. When the voltage selection switch in the 120V position, the generator
supplies 120V AC only. It can supply a full 30 amps to the 30 Amp receptacle
or 20A to the GFCI receptacle
lo
- 23 -