- Note the detector is more sensitive in cold weather.
- Make sure the sensor is not installed close to air-conditioner.
- Make sure the Time setting is not set to Test Mode position.
4. Lights stay on
- Light bulb sockets may be wired directly to the power source -Recheck the
wiring diagram.
- Adjust time to minimum, and ensure unit is firmly fixed to a solid object with
no moving branches etc. in field of view.
- Ensure detector is not being activated by stray moving heat sources such as
heating outlets.
- Fit the lens shield to eliminate triggering outside detection field.
- Reduce the sensitivity level.
5. Detector goes on under windy and rainy conditions
- Adverse weather conditions and temperature changes can result in unwanted
activations.
- This can be minimized by mounting in a protected location.
6. Maintenance and repair
- Do not attempt to repair as this could invalidate warranty or result in personal
injury.
- Clean detector lens and outside casing with damp cloth.