background image

GETTING STARTED

Each zone can independantly be turned ‘OFF’, set to ‘Alert Mode’ in which it

will give a chime tone, or set to sound a full and continuous tone in the ‘Alarm
Mode’.  When set in ‘Alarm Mode’ the LED for the zone that detects motion
willflash red. This alarm then continues for 30 seconds unless the alarm reset
button is pressed. You can alternate between settings by pressing the button
under each zone LED.

Page 2

Page 5

Attach the AC adaptor to the AC jack on the rear panel. Fully extend the

antenna and keep it vertical. Press the power button on the rear panel. The
Receiver Base will first run a self-test as it flashes the zone LED’s on the front
panel. Once the flashing stops the Receiver Base is ready to begin receiving
signals from the Motion Sensors.

NOTE: The Motion Sensors that come included with the kit are already set

to zones 1 and 2 and are marked accordingly. So you do not need to do anything
more except install the included batteries into the sensor and mount it in the
desired locations. If you want to reassign the sensors to a different zone or add
additional sensors, follow the instructions below.

NOTE: The Alarm Output provides a relay output which gives a momentary

closed signal when the receiver has a zone  in the ‘Alarm mode’ and an intrusion
is detected.

ADDING A NEW MOTION SENSOR TO A ZONE

1.

Press the ‘SENSOR DISCOVERY’ button found on the rear  panel of the

Receiver Base. The Power Light on the front panel of the Receiver Base will begin
flashing. This indicates the unit is waiting for a sensor to register itself.
2.

Connect a battery to ONE motion sensor, and as you do so the small LED

on the sensor will flash. When this occurs the Power Light on the Receiver Base
will stop  flashing. and all of the LED’s for the 3 zones will light up. (Note: only
power one motion Sensor at a time)
3.

Choose which zone you would like to register the sensor to and then simply

push the button under that LED. The sensor is now registered to that zone.

TECHNICAL SPECS

Manchester encoded 00K modulation with rolling code for security
Complies with Part 15. FCC ID

PIR:

Long range (7 metres at 20 

º

C) motion sensor with false

triggger reduction.

LED:

Flashes to indicate motion event.

Battery:

9V Alkaline (provided). Plus low battery alert.

Transmitter:

433 MHz @ FCC approved power limit.

Range:

60 metres outdoors, 12 metres indoors.

Temperature Range:

-10 

º

C to 40 

º

C.

Case:

High impact ABS.

Size:

136mm high, 36mm diameter. Plus stand.

APPROVALS

This device complies with part 15 FCC rules. Operation is subject to the

following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.

CE directive 93/68/EEC, EMC directive 89/336/EEC, LV directive73/23/EEC.
This class B digital apparatus complies with Canadian ICES-003.

This product has a twelve month manufacturers parts and labour warranty.  In the
unlikely event that you encounter a problem with this product, please telephone
the Voltek helpline on 09066 191 133*.  Should the problem not be able to be
resolved over the telephone it should be returned to the place of purchase or
direct to Voltek

.

WARRANTY

The user is cautioned that changes and modifications made to the equipment without
the approval of the manufacturer could void the products warranty.

Отзывы: