background image

Fault behaviour

 

Operating the solar charge controller is dangerous in the following situations:

 

The

 

solar

 

charge

 

controller

 

does

 

not

 

appear

 

to

 

function

 

at

 

all. 

The

 

solar

 

charge

 

controller

 

or

 

connected

 

cables

 

are

 

visibly

 

damaged. 

Emission

 

of

 

smoke

 

or

 

fluid

 

penetration. 

When

 

parts

 

are

 

loose. 

In

 

these

 

cases

 

immediately

 

remove

 

the

 

solar

 

charge

 

controller

 

from

 

the

 

solar

 

panels

 

and

 

battery.

 

 

Function

 

 

The

 

solar

 

system

 

controller is

 

designed

 

to: 

Monitor

 

the

 

state

 

of

 

charge

 

of

 

the

 

battery; 

Controls

 

the

 

charging

 

process, 

Control

 

the

 

connection/disconnection

 

of

 

loads, 

Make

 

sure

 

solar

 

system

 

works

 

at

 

proper

 

condition. 

 

Manual load switch with automatic re-start. 

 

Load is default setting ON. 

 

LED INDICATOR

 

 

 

LED

 

PANEL

 

Illuminate

 

green

 

when

 

solar

 

panel

 

is

 

charging

 

battery 

 

LED off, PV voltage less than Battery voltage or solar input polarity is connected in wrong way, solar input is cut off.

 

LED

 

BATTERY

 

Illuminate

 

green,

 

battery

 

is

 

good

 

and

 

voltage

 

of

 

battery

 

is

 

12.5-13.6V; 

 

Blink

 

in

 

green,

 

battery

 

is

 

fully

 

charge

 

and

 

in

 

float

 

charging

 

mode,

 

voltage

 

of

 

battery

 

is

 

13.6-14.4V.

 

Illuminate

 

orange,

 

battery

 

is

 

weak,

 

voltage

 

of

 

battery

 

is

 

11.5-12.5V 

Illuminate

 

red,

 

battery

 

is

 

empty,

 

voltage

 

of

 

battery

 

is

 

below

 

11.5V

 

LED

 

Question

 

Illuminate

 

red,

 

polarity

 

of

 

battery

 

is

 

connected

 

in

 

wrong

 

way, 

or the battery voltage is below 7.5V 

Blink

 

in

 

red, 

 

Battery

 

is

 

over

 

discharged,

 

can't

 

be

 

charged

 

again. 

 

 

Voltage

 

of

 

battery

 

is

 

higher

 

than

 

14.4V

 

or

 

battery

 

is

 

broken,

 

can’t

 

be

 

charged 

 

 

If

 

battery

 

is

 

over

 

current

 

charged(>10Amp)

 

more

 

than

 

3

 

second,

 

controller

 

will

 

cut

 

off

 

input

 

of

 

battery

 

and

 

Red

 

LED

 

blink

 

3

 

minutes

 

than

 

Red

 

LED

 

turn

 

off 

 

 

Over

 

voltage

 

of

 

solar

 

panel 

 

LED

 

off 

 

No

 

abnormality

 

detected

 

LED

 

Load

 

Illuminate

 

white,

 

system

 

provide

 

power

 

to

 

load

 

in

 

proper

 

way; 

 

Blink

 

in

 

white,

 

overload,

 

more

 

than

 

10Amp,

 

last

 

3

 

second,

 

controller

 

will

 

cut

 

off

 

output

 

automatically.

 

After

 

30 

seconds

 

blink,

 

LED

 

will

 

turn

 

off.

 

LED

 

off,

 

no

 

output

 

of

 

load.

 

 

 

Installation 

 

Danger

 

of

 

explosion

 

from

 

sparking!

 

Danger

 

of

 

electric

 

shock! 

 The

 

solar

 

charge

 

controller

 

may

 

only

 

be

 

connected

 

to

 

the

 

local

 

loads

 

and

 

the

 

battery

 

by

 

trained

 

personnel

 

and

 

in

 

accordance

 

with

 

the

 

applicable

 

regulations. 

 Follow

 

the

 

installation

 

and

 

operating

 

instructions

 

for

 

all

 

components

 

of

 

the

 

PV

 

system. 

 Ensure

 

that

 

no

 

cables

 

are

 

damaged. 

 Ensure

 

that

 

polarities

 

of

 

Solar

 

panel/battery/load

 

are

 

connected

 

in

 

proper

 

way. 

Содержание ISC1510

Страница 1: ...Installation and Operating Instructions Solar System Controller ISC1510...

Страница 2: ......

Страница 3: ...oller 3 Do not connect any defective or damaged measuring equipment 4 Follow the general and national safety and accident prevention regulation 5 Never alter or remove the factory plates and identific...

Страница 4: ...nate orange battery is weak voltage of battery is 11 5 12 5V Illuminate red battery is empty voltage of battery is below 11 5V LED Question Illuminate red polarity of battery is connected in wrong way...

Страница 5: ...and insert dowels 2 3 Fix the controller to the wall with the cable openings facing downwards using 5 oval head screws M4x35 DIN 7996 Install the solar system and operating mode Connect the wires in...

Страница 6: ...ervoltage protection Solar panel reverse current protection The following installation faults do not destroy the controller After correcting fault the device will continue to operate correctly Overcha...

Страница 7: ...d Load output is switched off due to excessive load current Remedy Reduce load current if necessary switch off or disconnect loads Check loads Load output is switched off due to short circuit at load...

Страница 8: ...should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Specifications are subject to change without prio...

Отзывы: