background image

 

About this manual 

 
 
 
These operating instructions come with the product and shall be kept along it for all the life of the product for a 
proper installation and usage of it. 
 

Read these operating instructions carefully before use, 

Keep them over the entire life of the product, 

And pass them on to any future owner or user of this product. 

 
 

This manual describes the installation, function, operation and maintenance of the solar system controller 

ISC1510. 

 
 

These operating instructions are intended for end customers. A technical expert must be consulted in cases 

of uncertainty. 

 

 

Safety

 

 
 

1. The solar controller may only be used in PV systems for charging and controlling Lead-Acid batteries. 

2. No energy source other than a solar generator may be connected to the solar charge controller. 

3. Do not connect any defective or damaged measuring equipment. 

4. Follow the general and national safety and accident prevention regulation. 

5. Never alter or remove the factory plates and identification labels. 

6. Keep children away from PV systems. 

7. Never open the device. 

8. One set solar module can connect with one controller only. 
9. Never

 

touch

 

bare

 

cables

 

ends. 

 
 
 

Other risks

 

 
 

Danger of fire and explosion

 

Do not use the solar charge controller in dusty environments, in the vicinity of solvents or where 

inflammable gases and vapors can occur. 

No open fires, flames or sparks in the vicinity of the batteries. 

Ensure that the room is adequately ventilated. 

Check the charging process regularly. 

Follow the charging instructions of the battery manufacturer. 

 

 

Battery acid

 

Acid splashes on skin or clothing should be immediately treated with soap suds and rinsed with 

plenty of water. 

If acid splashes into the eyes, immediately rinse with plenty of water. Seek medical advice. 

 

 

 
 
 
 
 

Содержание ISC1510

Страница 1: ...Installation and Operating Instructions Solar System Controller ISC1510...

Страница 2: ......

Страница 3: ...oller 3 Do not connect any defective or damaged measuring equipment 4 Follow the general and national safety and accident prevention regulation 5 Never alter or remove the factory plates and identific...

Страница 4: ...nate orange battery is weak voltage of battery is 11 5 12 5V Illuminate red battery is empty voltage of battery is below 11 5V LED Question Illuminate red polarity of battery is connected in wrong way...

Страница 5: ...and insert dowels 2 3 Fix the controller to the wall with the cable openings facing downwards using 5 oval head screws M4x35 DIN 7996 Install the solar system and operating mode Connect the wires in...

Страница 6: ...ervoltage protection Solar panel reverse current protection The following installation faults do not destroy the controller After correcting fault the device will continue to operate correctly Overcha...

Страница 7: ...d Load output is switched off due to excessive load current Remedy Reduce load current if necessary switch off or disconnect loads Check loads Load output is switched off due to short circuit at load...

Страница 8: ...should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Specifications are subject to change without prio...