The setting options are:
¬
None/disabled: The input value is not transferred.
¬
Direct output: The input value is directly linked to the output, i.e. Input 1 to Output 1 or Input 2 to Output 2.
¬
Opposite output: The input value is linked to the opposite output, i.e. Input 1 to Output 2 or Input 2 to Output 1.
¬
Both outputs: The selected input controls both outputs.
¬
Normal: It sets the input behaviour. In case of Normal, log 1 on the input means switching on the output.
¬
Reversed: It sets the input behaviour. In case of Reversed, log 1 on the input means switching off the output.
The changes in the setting are reflected immediately in the transferred data and the internal states of both modules,
i.e. the setting can be tested on the running modules.
Option: [4] Save settings
The last option enables saving the master module setting to the internal memory. This setting is then loaded once the
power supply is on. The result of the option is either ok or fail. The result fail means the processor internal memory
error, i.e. the written data do not match the read data.
Selection :˙4
> saving ....
> ok.
----- DIO Terminal -----
[1] List digital inputs
[2] Slave settings list
[3] Change slave setting
[4] Save settings
Selection :
SWITCH SETTING
The DIP switch on the ShiftGuard motherboard is used for setting the basic modem properties. The DIP switch enables
setting three types of parameters.
- Selecting Master/Slave or Transmitter/Receiver
- Selecting the function on the RS485 serial interface between the parameterization console and forwarding the data
communication part
- Setting the Slave unit address. Setting the Master unit address makes no sense as the Master unit transmits only for
the selected Slave addresses
DIP switch position
1
2
3
4
5
6
Select Master (0)
Or Slave (1)
Select forwarding of data communication part (0)
or configuration console (1)
Address
The position of a logical 0/logical 1 on the DIP switch. The switch on the DIP switch is switched on in logical 1 position.