BLOCK DIAGRAM

DESCRIPTION

The PLC_IN and PLC_OUT modems are primarily used for transmitting the signal within the 

VoltGuard

 electric vehicle 

charging infrastructure system. They can also be used as the replicators of digital signals in a wide range of applica-
tions. For example, they are used to transmit the tariff signal to the appliances switched on only at the particular tariff 
period. This solution can replace the cabling that is difficult to install, for example, in historical houses or new large 
buildings. 

VOLTGUARD SYSTEM

The 

VoltGuard

 system is used for optimization of electric vehicle charging in areas with limited charging current values. 

A typical example is a detached house with its own consumption that needs to charge an electric vehicle. In this case 
you can set a very low available current capacity, so that the usual activities of the residents were not limited and the 
electric vehicle charging was not significantly delayed. Or you can install the 

VoltGuard

 system that always sets the 

maximum residual current value on the charging station (residual current = total input breaker capacity – immediate 
home consumption) and regulates it dynamically according to household operations. The communication between the 
HomeGuard residual capacity meter and the PortGuard charging control unit can be done by means of a twisted pair or 
the PLC communication using the ShiftGuard modules.
The communication between the HomeGuard and the PortGuard modules is done by means of RS485 twisted pair. 
Before it is connected, you have to set the modem connected to the HomeGuard module as the Master modem and the 
modem connected to the PortGuard module as the Slave modem. The modems communicate with sufficient frequency 
to ensure reliable dynamic switching of the residual current value in the PortGuard module. 

2 x 230V AV

input

2 x 16A relay

output

DIP switch

domain/address

Control  

microprocessor

PLC modem

LED indication

RS485

AC/DC

power supply

Содержание ShiftGuard

Страница 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Страница 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Страница 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Страница 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Страница 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Страница 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Страница 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Страница 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Страница 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...

Отзывы: