> Slave 5, master input 2 controls : direct and normal
> Slave 6, master input 1 controls : direct and normal
> Slave 6, master input 2 controls : direct and normal
> Slave 7, master input 1 controls : direct and normal
> Slave 7, master input 2 controls : direct and normal
> Slave 8, master input 1 controls : direct and normal
> Slave 8, master input 2 controls : direct and normal
> Slave 9, master input 1 controls : direct and normal
> Slave 9, master input 2 controls : direct and normal
> Slave 10, master input 1 controls : direct and normal
> Slave 10, master input 2 controls : direct and normal
> Slave 11, master input 1 controls : direct and normal
> Slave 11, master input 2 controls : direct and normal
> Slave 12, master input 1 controls : direct and normal
> Slave 12, master input 2 controls : direct and normal
> Slave 13, master input 1 controls : direct and normal
> Slave 13, master input 2 controls : direct and normal
> Slave 14, master input 1 controls : direct and normal
> Slave 14, master input 2 controls : direct and normal
> Slave 15, master input 1 controls : direct and normal
> Slave 15, master input 2 controls : direct and normal
----- DIO Terminal -----
[1] List digital inputs
[2] Slave settings list
[3] Change slave setting
[4] Save settings
Selection :

Option: [3] Change slave setting

This item in the menu enables setting the properties of logical 0 and logical 1 interpretation on the DIG_IN input and the 
way it is transferred to the output. Once the option “Change slave setting” is selected, you must enter the number of 
the slave device for which the setting is to be changed, i.e. in the following list, it is the line “Enter slave (e = exit):” with 
entered option 0 and then you are asked to select Input 1 or 2. The list is displayed as follows:

Selection :3
Enter slave (e = exit) :˙0
> Slave 0. Select input:
[1] Input 1
[2] Input 2
[e] Exit
Selection :

Once you select the channel for which you want to change the setting, the first part lists the device and the input you 
change the setting on, see:

> Slave 0, master input 2

Next the current setting of both inputs is listed, see:

> Slave 0, master input 1 controls : disabled and normal
> Slave 0, master input 2 controls : both and normal

The list for both channels is displayed because the setting of one channel can affect the setting of the other channel. 
The final list of the setting options for a particular input is displayed as follows:

Selection :2
> Slave 0, master input 2
> Slave 0, master input 1 controls : disabled and normal
> Slave 0, master input 2 controls : both and normal
[0] None/disabled
[1] Direct output
[2] Opposite output
[3] Both outputs
[4] Normal
[5] Reversed
[e] Exit
Selection :

Содержание ShiftGuard

Страница 1: ...dual Capacity Meter and the PortGuard charging control unit can also be done by means of RS485 twisted pair bus however such a cable is usually not installed between the input of the power supply poin...

Страница 2: ...available current capacity so that the usual activities of the residents were not limited and the electric vehicle charging was not significantly delayed Or you can install the VoltGuard system that...

Страница 3: ...available after stabilizer 3 Red True value read at IN2 input True value on DIGIOUT2 LED indicator on the device receives information on Log1 from the counterparty the state corresponds to the relay...

Страница 4: ...he processor interprets the digital inputs DIG_IN1 and DIG_IN2 In case the number 1 is displayed 230V 50Hz voltage is connected on the DIG_IN input Once the values are listed the basic menu is auto ma...

Страница 5: ...rminal 1 List digital inputs 2 Slave settings list 3 Change slave setting 4 Save settings Selection Option 3 Change slave setting This item in the menu enables setting the properties of logical 0 and...

Страница 6: ...saving the master module setting to the internal memory This setting is then loaded once the power supply is on The result of the option is either ok or fail The result fail means the processor intern...

Страница 7: ...communication cable The cables with a suitable cross section are connected according to the diagram in the chapter Connection diagram and LED indication Connection of RS485 line with HomeGuard Master...

Страница 8: ...time for input change max 2 s RS485 communication Type RS485 twisted pair physical layer Communication line parameters 9600 baud 8n1 RS485 serial line power supply internal RS485 twisted pair replace...

Страница 9: ...ot be operated with other voltage current or frequency than it was produce or professionally mod ified for The product must be placed and secured so that it is difficult to access or inaccessible for...

Отзывы: