16
9. COMMISSIONING
a) Connection to a Voltage/Current Supply
Attention!
Always connect the charger to the voltage/current supply first; only then must a rechargeable battery be
connected to the charger.
The charger offers two different options for operation:
• Operation via the mains voltage (100 - 240 V/AC, 50/60 Hz)
• Operation via stabilised direct voltage (11 - 18 V/DC, e.g. via an external vehicle lead battery or a mains adapter)
Never use both operating modes at the same time. This may damage the charger. Loss of guarantee/
warranty!
The charger has a maximum charging output of 50 W. If the charger is to be operated via the direct voltage input,
the power supply strength must be chosen depending on how high the actually used charging output is (depending
on the rechargeable battery type, cell number and the charging current set).
When fully using the maximum charging power of 50 W, the conversion loss leads to an approx. 20% - 30%
higher power intake.
If the charger is not to be operated at a 12 V vehicle lead battery, but via a fixed voltage mains unit, it must be
able to supply a correspondingly high current (we suggest at least 6,5 A).
When using the direct current input, observe the correct polarity when connecting (plus/+ and minus/-).
The charger will switch on automatically after connecting to the voltage/
current supply. The display will light up; the start message will appear (see
picture on the right) and the charger will emit a brief signal sound.
The charger then is in its main menu.
VOLTCRAFT
V-CHARGE 50
Содержание V-CHARGE 50
Страница 1: ...MULTI FUNCTION CHARGER V CHARGE 50 OPERATING INSTRUCTIONS Item No 1416554 VERSION 08 16...
Страница 20: ...20 10 MENU STRUCTURE...
Страница 47: ...47...