background image

Operation

a) Inserting / replacing batteries

•  Remove the battery compartment cover 

(8)

.

•  Insert 2x AAA batteries, matching polarity as 

shown inside the battery compartment.

•  Replace the battery compartment cover 

(8)

.

  Replace the batteries when “LO” 

appears on the LCD display 

(1)

.

b) Weighing

•  Place the scale on a stable, horizontal and even 

surface.

•  Carefully slide the protective cover 

(3)

 off. Close 

after use

•  Touch 

ON/OFF (4)

 to turn the scale on, and wait 

until “0.00” is shown. If another value appears 

Touch 

TARE (6)

.

•  Touch 

MODE (5)

 to toggle through units of 

measurement (

g, oz, ozt, dwt, ct, gn

).

•  Place the object you wish to weigh on the weighing 

platform 

(2)

. If the weight exceeds the weighing 

range, the LCD display 

(1)

 will show “O”. If this 

happens remove the object from the weighing 

surface immediately.

•  Touch 

ON/OFF (4)

 to turn the scale off.

 

The scale turns off automatically after 

approximately 2 minutes of inactivity.

c) Tare Function

  The weighing capacity includes the 

weighing container. It is recommended 

to use a weighing container which is as 

light as possible.

The tare function is used to measure net weight when 

using a container. The tare function factors in the 

weight of the container so the scale only measures 

the net weight of the object you wish to weigh.
•  Touch 

ON/OFF (4)

 to turn the scale on, then place 

an empty measuring container (bowl, basket, etc.) 

on the weighing platform 

(2)

. Wait until the LCD 

display 

(1)

 stabilizes.

•  Touch 

TARE (6)

. The display will show the value 

“0.00” including the measuring container.

•  Place the object you wish to weigh in the 

measuring container. The displayed weight will be 

the net weight of the object you are weighing.

•  To continue weighing without the measuring 

container, remove the container from the weighing 

surface and Touch 

TARE (6)

.

d) Counting Function

This function determines the quantity of units of an 

equal weight.
•  Touch 

ON/OFF (4)

 to turn the scale on.

•  Place (25, 50, 75 or 100)  objects on the weighing 

platform 

(2)

.

•  Touch and hold 

PCS (7)

 until the number “25” 

appears on the LCD display.

•  Touch 

MODE (5)

 to set a reference unit number 

(25, 50, 75 or 100).

•  Touch 

PCS (7). 

The LCD display 

(1)

 will show the 

number of units.

•  Add or remove objects from the weighing platform 

(2)

.

•  Touch 

MODE (5)

 to return to normal weighing 

mode. 

 

The reference value will be stored until 

you set a new value.

e) Calibration

  The scale has been calibrated at 

the factory. If accuracy fails, first try 

replacing the batteries.

 

A standard test weight of 

200g

 (not 

included) is required for calibration.

 

The weighing platform 

(2)

 must be empty. 

•  Touch 

ON/OFF (4)

 to turn the scale on. 

•  Touch and hold 

MODE (5)

 until the LCD display 

(1)

 shows “CAL”.

•  Touch 

MODE

 

(5)

 again. “CAL” will flash on the 

LCD display 

(1)

, followed by “

200g

” which is the 

weight you need to put on the weighing platform 

(2)

•  Place the calibration weight on the weighing 

platform 

(2)

. Calibration is completed when 

“PASS” appears on the LCD display 

(1)

.

•  If a calibration error has occurred, “FAIL” will 

show on the LCD display 

(1)

. Please repeat the 

calibration process.

•  Remove the calibration weight from the weighing 

platform 

(2)

 and turn off the scale.

Care and Cleaning

•  The product is maintenance-free except for 

potential battery replacement and occasional 

cleaning.

•  Do not use any aggressive cleaning agents, 

rubbing alcohol or other chemical solutions as 

they can cause damage to the housing and 

malfunctioning.

•  Clean the product with a dry, fibre-free cloth.

Disposal

a) Product

  Electronic devices are recyclable 

waste and must not be disposed of in 

the household waste. At the end of its 

service life, dispose of the product in 

accordance with applicable regulatory 

guidelines.

 

Remove any inserted batteries and 

dispose of them separately from the 

product.

b) Batteries

  You as the end user are required by 

law (Battery Ordinance) to return all 

used batteries. Disposing of them in the 

household waste is prohibited.

 

Contaminated batteries are labeled with 

this symbol to indicate that disposal in 

the domestic waste is forbidden. The 

designations for the heavy metals 

involved are: Cd = Cadmium, Hg = 

Mercury, Pb = Lead (name on batteries, 

e.g. below the trash icon on the left).

Used batteries can be returned to collection points 

in your municipality, our stores or wherever batteries 

are sold.
You thus fulfill your statutory obligations and 

contribute to the protection of the environment.

Technical Data

Power supply .......................2 x AAA battery
Battery life ............................Up to 6 months
Operating current .................1.52 mA
Weighing range ...................0.05 – 

200 g

Resolution ............................0.01 g
Accuracy ..............................± 0.03 g
Auto shut-off ........................2 mins
Measuring units ...................g, oz, ozt, dwt, ct, gn 
Operating conditions ............ 5 to +40 ºC, 0 – 70% 

RH (non-condensing)

Storage conditions ............... -10 to +60 ºC, 0 – 85% 

RH (non-condensing)

LCD (W x H) ........................48 x 30 mm
Weighing platform (W x H) ..57 x 70 mm

Dimensions (L x W x H) .......125 x 68 x 18 mm
Weight .................................116 g (without batteries)

 Operating Instructions

Pocket Scale PS-

200

Item No. 1782519

Intended Use

This product is designed to weigh objects with a max. weight of 200g. Power is supplied via 2 AAA batteries.
The product is not intended for medicinal or commercial use. It is intended for indoor use only. Do not use it 

outdoors. Contact with moisture, e.g. in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for 

purposes other than those described above, the product may be damaged. Read the instructions carefully 

and store them in a safe place. Make this product available to third parties only together with its operating 

instructions.
This product complies with the statutory national and European requirements. All company names and 

product names are trademarks of their respective owners. All rights reserved.

Delivery Content

•  Scale
•  Cover

•  2x 1.5 V batteries (type AAA)
•  Operating instructions

Up-to-date Operating Instructions           

Download the latest operating instructions at www.conrad.com/downloads or scan the 

QR code shown. Follow the instructions on the website.

Explanation of Symbols

 

The symbol with the exclamation mark in the triangle is used to indicate important information in 

these operating instructions. Always read this information carefully.

 

The arrow symbol indicates special information and advice on operation.

Safety Instructions

Read the operating instructions carefully and 

especially observe the safety information. If 

you do not follow the safety instructions and 

information on proper handling in this manual, 

we assume no liability for any resulting personal 

injury or damage to property. Such cases will 

invalidate the warranty/guarantee.

a) General Information

•  The product is not a toy. Keep it out of the reach of 

children and pets.

•  Do not leave packaging material lying around 

carelessly. This may become dangerous playing 

material for children.

•  Protect the product from extreme temperatures, 

direct sunlight, strong jolts, high humidity, 

moisture, flammable gases, steam and solvents.

•  Do not place the product under any mechanical 

stress.

•  If it is no longer possible to operate the product 

safely, take it out of operation and protect it from 

any accidental use. Safe operation can no longer 

be guaranteed if the product:

 - is visibly damaged,
 - is no longer working properly,
 - has been stored for extended periods in poor 

ambient conditions or

 - has been subjected to any serious 

 

transport-related stresses.

•  Please handle the product carefully. Jolts, impacts 

or a fall from a low height can damage the product.

•  Maintenance, modifications and repairs must only 

be completed by a technician or an authorised 

repair centre.

•  If you have questions which remain unanswered by 

these operating instructions, contact our technical 

support service or other technical personnel.

•  Operation in environments with strong 

electromagnetic fields may result in incorrect 

displayed values.

•  Do not leave objects you wish to weigh on the 

scale for too long and do not overload the scale. 

The measuring element could be damaged.

b) Batteries

•  Correct polarity must be observed while inserting 

the battery.

•  The batteries should be removed from the product 

if it is not used for a long period of time to avoid 

damage through leaking. Leaking or damaged 

batteries might cause acid burns when in contact 

with skin, therefore use suitable protective gloves 

to handle corrupted batteries.

•  Batteries must be kept out of reach of children. Do 

not leave batteries lying around, as there is risk, 

that children or pets swallow them.

•  All batteries should be replaced at the same time. 

Mixing old and new batteries in the product can 

lead to battery leakage and product damage.

•  Batteries must not be dismantled, short-circuited or 

thrown into fire. Never recharge non-rechargeable 

batteries. There is a risk of explosion!

Operating Elements

1

2

3

4 5 6

7

8

1  LCD display
2  Weighing platform
3  Protective cover
4   

ON/OFF

5   

MODE

6   

TARE

7   

PCS

8  Battery compartment cover

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represents the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE. 

*1782519_v4_01319_02_dh_m_en

Содержание PS-200

Страница 1: ...laufzeit bis zu 6 Monate Betriebsstrom 1 52 mA Wiegebereich 0 05 200 g Auflösung 0 01 g Genauigkeit 0 03 g Abschaltautomatik 2 Minuten Maßeinheiten g oz ozt dwt ct gn Betriebsbedingungen 5 bis 40 ºC 0 70 rF nicht kondensierend Lagerungsbedingungen 10 bis 60 ºC 0 85 rF nicht kondensierend LCD B x H 48 x 30 mm Wiegeplattform B x H 57 x 70 mm Abmessungen L x B x H 125 x 68 x 18 mm Gewicht 116 g ohne ...

Страница 2: ...ons 5 to 40 ºC 0 70 RH non condensing Storage conditions 10 to 60 ºC 0 85 RH non condensing LCD W x H 48 x 30 mm Weighing platform W x H 57 x 70 mm Dimensions L x W x H 125 x 68 x 18 mm Weight 116 g without batteries Operating Instructions Pocket Scale PS 200 Item No 1782519 Intended Use This product is designed to weigh objects with a max weight of 200g Power is supplied via 2 AAA batteries The p...

Страница 3: ...gn Conditions d utilisation 5 à 40 C 0 à 70 d humidité relative sans condensation Conditions de stockage 10 à 60 C 0 à 85 d humidité relative sans condensation LCD L x H 48 x 30 mm Plateforme de pesée L x H 57 x 70 mm Dimensions L x l x H 125 x 68 x 18 cm Poids 116 g sans piles Mode d emploi BALANCE DE POCHE PS 200 N de commande 1782519 Utilisation prévue Ce produit est conçu pour peser des objets...

Страница 4: ...rijfsomstandigheden 5 tot 40 C 0 70 RH niet condenserend Opslagomstandigheden 10 tot 60 C 0 85 RH niet condenserend LCD B x H 48 x 30 mm Weegplateau B x H 57 x 70 mm Afmetingen L x B x H 125 x 68 x 18 mm Gewicht 116 g zonder batterijen Gebruiksaanwijzing Zakweegschaal PS 200 Bestelnr 1782519 Beoogd gebruik Dit product is ontworpen voor het wegen van voorwerpen met een max gewicht van 200g De voedi...

Отзывы: