Connection and Operation 

Check for matching voltage specifications on the inverter and the desired load devices. 
Use only wire of sufficient cross-section for the DC-leads and make sure to have generous connecting surface between the wire and the DC-
connectors.  

Caution: To achieve proper electrical contact between the bolts and the printed circuit board, always fasten the nuts of the DC connectors 
(figure 1) even if only used for testing purposes. 

Check for adequate air clearances at the ventilation slots to ascertain sufficient cooling. Never cover the ventilation slots and never operate the 
device near combustible materials. 
Connect the inverter with the DC power supply and switch it on. If everything is connected properly and operated within specified parameters, the 
green LED will light up. 
 

General notes on operating AC loads with inverters 

In general, all AC loads may be operated with inverters. To estimate the power requirements and necessary reserves, one needs to know some 
characteristics of typical AC loads. Most AC loads have been designed for mains operation. One important item to note however is the required 
inrush current which does not play a big role when operated on mains voltage since the mains grid is capable of delivering very large currents. 
Manufacturers therefore do not focus on inrush current. The inrush current however may exceed the nominal rated value by a multiple. 

 

Incandescent lamps up to 8x higher inrush current within 1 sec  

 

Refrigerators up to 10x higher inrush current within 3 sec  

 

Television sets up to 10x higher inrush current within 1 sec  

Therefore it is important to choose the inverter for sufficient power reserves. For example an inverter supposed to supply a small refrigerator of 50W 
nominal power has to deliver a peak power of 500W. 
 

Reverse Polarity Protection 

In case the DC input is accidentally connected with reversed polarity the current is flowing across a diode and triggers the fuse. In this case the 
proper polarity must be established and the fuse replaced. 
 

Replacing the Fuse 

The fuses are located under the DC connector cover (12V: 40A; 24V: 20A). In case the fuse is blown the inverter has to be disconnected and the 
fuse replaced with a new one of the same current rating. Subsequently check the device without any load connected. In case the fuse blows again 
the device is defective and has to be repaired by an authorized technician. 
 

Remote control 

To connect the remote control we suggest stranded wire of 2, x 0,5mm². The cable may be extended up to a length of 10m. You may use any switch 
as ON/OFF switch, since the internal 12V direct voltage is used as switching voltage. 
 

Recommended minimum DC wire cross-section 

 

 

up to 2m  

3m  

 

 

 

 

 

 

PT300 / PT600

 

16mm² 

 

16mm² 

 

 

 

 

 

 

PT1200

   

25mm² 

 

35mm² 

 

 

 

 

 

 

PT2000

   

35mm² 

 

50mm² 

 
Technical Data: 
 

 

 

 

 

PT300-12V 

PT300-24V 

PT600-12V 

PT600-24V  

Nominal input voltage: 

 

 

12V 

 

24V 

 

12V 

 

24V 

Min./max. input voltage: 

 

 

11-15V   

22-30V 

 

11-15V   

22-30V  

Typical current consumption:   

 

0,5W 

 

0,5W 

 

0,5W 

 

0,5W 

DC fusing: 

 

 

 

1 x 40A   

1 x 20A   

2 x 40A   

2 x 20A  

Continuous output power: 

 

 

300W 

 

300W 

 

600W 

 

600W 

Maximum output power: 

 

 

800W 

 

800W 

 

1200W   

1200W 

AC output voltage:   

 

 

225V 

 

225V 

 

225V 

 

225V 

Output voltage tolerance [+/-%] @ 12V DC IN:  

5% 

 

5% 

 

5% 

 

5% 

Output frequency / tolerance:  

 

50Hz +/-1% 

50Hz +/-1% 

50Hz +/-1% 

50Hz +/-1% 

Fan cooling: 

 

 

 

no 

 

no 

 

yes 

 

yes 

Remote control connector: 

 

 

yes 

 

yes 

 

yes 

 

yes 

Dimension mm:  

 

 

 

220 x 245 x 70 

220 x 245 x 70 

220 x 245 x 70 

220 x 245 x 70 

Weight:   

 

 

 

2,2 kg 

 

2,2 kg 

 

2,4 kg 

 

2,4 kg 

 
 

 

 

 

 

 

PT1200-12V 

PT1200-24V 

PT2000-12V 

PT2000-24V  

Nominal input voltage: 

 

 

12V 

 

24V 

 

12V 

 

24V 

Min./max. input voltage: 

 

 

11-15V   

22-30V 

 

11-15V   

22-30V  

Typical current consumption:   

 

0,5W 

 

0,5W 

 

0,5W 

 

0,5W 

DC fusing: 

 

 

 

4 x 40A   

4 x 20A   

8 x 40A   

8 x 20A  

Continuous output power: 

 

 

1200W   

1200W 

 

2000W   

2000W 

Maximum output power: 

 

 

2000W   

2000W 

 

3500W   

3500W 

AC output voltage:   

 

 

225V 

 

225V 

 

225V 

 

225V 

Output voltage tolerance [+/-%] @ 12V DC IN:  

5% 

 

5% 

 

5% 

 

5% 

Output frequency / tolerance:  

 

50Hz +/-1% 

50Hz +/-1% 

50Hz +/-1% 

50Hz +/-1% 

Fan cooling: 

 

 

 

yes 

 

yes 

 

yes 

 

yes 

Remote control connector: 

 

 

yes 

 

yes 

 

yes 

 

yes 

Dimension mm:  

 

 

 

400 x 245 x 70 

400 x 245 x 70 

505 x 245 x 70 

505 x 245 x 70 

Weight:   

 

 

 

3,6 kg 

 

3,6 kg 

 

5,2 kg 

 

5,2 kg 

 
 
 
 
 
 
 
 

We reserve the right to make technical alterations. We assume no liability for typing errors. 10/2004. 

Conrad Electronic GmbH, Klaus-Conrad-Str. 1, D-92240 Hirschau, Germany 

Phone: (49) 180 – 5312111, Fax: (49) 180 – 5312110  Email: [email protected] 

  Internet: www.conrad.de 

Содержание Power-Terminal PT300

Страница 1: ...gsklemmen und der Schaltung herzustellen bitte Muttern des Schraubterminals 1 Eingang auch f r Testzwecke immer fest anziehen Kurzbeschreibung Die Spannungswandler der Power Terminal Familie sind mode...

Страница 2: ...t der Strom ber eine Diode und die Sicherung spricht an In diesem Fall muss die Verpolung entfernt werden und die Sicherung getauscht werden Sicherungswechsel Unter der Abdeckung f r die DC Anschl sse...

Страница 3: ...ays fasten the nuts of the DC connectors figure 1 even if only used for testing purposes Description Inverters of the Power Disc family are modern computer controlled devices especially suited for mob...

Страница 4: ...the Fuse The fuses are located under the DC connector cover 12V 40A 24V 20A In case the fuse is blown the inverter has to be disconnected and the fuse replaced with a new one of the same current rati...

Страница 5: ...on Pour tablir un contact s r entre les bornes d entr e et la connexion veuillez toujours visser fermement les crous du terminal filet 1 entr e m me pour faire un test Br ve description Les transforma...

Страница 6: ...t de l entr e DC est invers e lors du branchement le courant passe par une diode et le fusible saute Dans ce cas il faut r tablir la bonne polarit et remplacer le fusible Remplacement du fusible Les f...

Страница 7: ...ltijd vast aan te draaien Korte beschrijving De spanningsomzetters van de Power Terminal familie zijn moderne door microcontrollers bestuurde toestellen die speciaal voor het mobiele gebruikt ontwikke...

Страница 8: ...de en spreekt de zekering aan In dit geval moet die ompoling ongedaan gemaakt worden en de zekering vervangen worden Vervanging van de zekering Onder de afdekking voor de DC aansluitingen van het toes...

Отзывы: