35
Error messages when measuring voltage:
If the voltage of a cell falls below the threshold
value set on the device (LiPo: 3.00 V;
LiFe: 2.50 V; LiIon: 3.00 V), the display says
“LOW VOL” and the Power Analyzer emits an
acoustic warning.
If the voltage of a cell falls above the threshold
value set on the device (LiPo: 4.24 V;
LiFe: 3.65 V; LiIon: 4.14 V), the display says
“HIGH VOL”.
If the voltage differences of the individual cells
are above 50 mV, the display says
“UNBALANCED”. In this case use the device’s
balancer function.
If the battery’s balancer plug is removed and the
Power Analyzer was first connected to a second
voltage source, the message
“CONNECT BAT” appears.
LiPo-3S
12.470V
97% UNBALANCED
LiPo-3S
13.270V
100%
HIGH VOL
LiPo-3S
8.520V
0%
LOW VOL
LiPo-0S
0.000V
0% CONNECT BAT
Figure 9